Preparation work and installation box

For problem-free operation of the appliance, it is impor-
tant for the bottom edges of the installation box and the
heater base to be on the same plane, and the base to be posi-
tioned in accordance with the installation template so that the
control knob is not too high or too low.
Attach the installation template to the floor of the installation
cut-out for the installation box. The arrow must point exactly
to the leading edge of the cut-out (R = right-hand installation,
L = left-hand installation).
Saw out the floor cut-out and prepare the 5 points for the fas-
tening screws.
Seal interfaces and allow them to dry completely. Do not use
any flammable / heat-sensitive materials.
Fig. A (right-hand installation) / fig. B (left-hand installation)
Insert the frame halves (4) into the floor cut-out, push out-
wards and screw down (pretension by bending open the legs
beforehand if necessary so that the frame sits properly).
The sealing means that an additional seal between the frame
halves and the floor is not required.
If the vehicle manufacturer stipulates a seal, surplus
sealing material, particularly detached threads, must be
removed. Do not use any flammable / heat-sensitive
materials.
Break out the pre-punched breakthrough for the exhaust
duct on the installation box (1) (R = right-hand installation,
L = left-hand installation). The exhaust duct of the S 5004
heater can also be led through from the side if the installa-
tion depth is low (R1 or L1).

S 3004

1
T
R
U
L
Figure 4
If a Truma fan is being installed, remove the cover T and
preinstall the fan on the installation box in accordance
with the supplied installation instructions. If a Truma Ultraheat
additional electric heater is being installed, remove the cover U
and preinstall the additional electric heater on the installation
box in accordance with the supplied installation instructions.
S 5004
1
T
R1
U R
L1
L
S 3004
Break out the pre-punched breakthrough for the control rod (7)
on the installation box (1) (DR = right-hand installation, DL =
left-hand installation).
It is essential to close off any unintentionally broken-out
unused DR / DL breakthroughs, using suitable material.
– Attach the fan (20) to the installation box with 3 screws
(3.5 x 19).
– Place support (60) onto base (1a) of the installation box and
engage.
Internal control panel
– Push the control panel cable (23 – silicone) for the fan
through the recess in the support and clip it into the pro-
vided cable guide.
External control panel
– The control panel cable (no picture) must not touch the
heater, the fan or the warm air duct. Secure the cable
properly.
– Secure the installation box (1) in the installation cut-out with
6 screws (3 x 12), each angled towards the outside. If this is
not possible, the installation box can be secured at the side
to the front of the installation cut-out with 4 screws.
– Secure the support (60) with 3 screws (3.5 x 16).
– Fit the cover (61) to the 2 centring aids (60a) on the support.
Swivel in from above until it snaps into position.
DL
1a
3 x
2 x
3 x
23
60
60a
7
60
61
Figure 5
20
1
DR
2x
1a
20
23
3 x
3 x
1a
19