Setting The Cleaning Controls; Brush Overload (Over Current) - Numatic TTB 1840 Mode D'emploi

Masquer les pouces Voir aussi pour TTB 1840:
Table des Matières

Publicité

To activate the control panel: press the

Setting the cleaning controls

1
cycle button or press a trigger (Fig.26).
(Fig.27a)
(Fig.27b)
(Fig.27c)
(Fig.27d)
1
Fig.26
To start: hold down either trigger and press the yellow start
button once (Fig.26).
Whilst the brush motor is running press the tap On / Off
button for fluid control (Fig.27a), the clean tank tap must be
open.
Ideally set the tap to 45º (Fig.27) this enables the cleaning
solution to last the same time as a fully-charged battery.
When the triggers are released the brush motor and the
cleaning solution pump will switch off, the vacuum motor will
continue for 10 seconds.
Press the
cycle button to operate the brush only
(Fig.27b).
The start sequence is required in this mode.
The tap button will operate in this mode.
Press the cycle button again to get vacuum only.
The start button and triggers are not required in this mode.
(Fig.27c)
Press the cycle button to switch this mode off and return to
default mode.
The panel if unused will automatically turn off after 60
seconds.
Brush overload.
The brush LED light will flash if the brush motor has been
overloaded (Fig.27d).
Releasing the handle triggers will allow the machine to stop
and reset.
If the brush motor keeps overloading consider using
a different type of brush. Heavy brush load decreases
the available battery run time.
32
45
0
Fig.27

Publicité

Table des Matières
loading