INSTALLATION INSTRUCTIONS (continued)
 
INSTALLATION DRAWING  
  
The minimum hood distance above a cooktop surface must  
be no less than 28'' and no higher than 30".   
  
  
  
  
  
 
 
 
 
  
 
   
 
ELECTRICAL INSTALLATION  
 
 
WARNING 
 
 
 
THIS RANGE HOOD MUST BE PROPERLY GROUNDED. TURN OFF ELECTRICAL POWER AT SERVICE ENTRANCE 
BEFORE WIRING.  CHECK TO MAKE SURE THAT THE ELECTRIC CHORD IS NOT IN CONTACT WITH THEE SHARP 
EDGES OF THE APPLIANCE.  
 
 
IMPROPER GROUNDING CAN RESULT IN A RISK OF ELECTRIC SHOCK. CONSULT A QUALIFIED ELECTRICIAN IF 
THE  GROUNDING  INSTRUCTIONS  ARE  NOT  COMPLETELY  UNDERSTOOD  OR  IF  THERE  IS  DOUBT  AS  TO 
WHETHER THE APPLIANCE IS PROPERLY GROUNDED.  DO NOT USE AN EXTENSION CORD. IF THE POWER 
SUPPLY CORD IS TOO SHORT, HAVE A QUALIFIED ELECTRICIAN INSTALL AN OUTLET NEAR THE APPLIANCE.  
  
  
 This appliance must be plugged into an outlet that is properly installed and grounded.  In the event 
of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire 
for  the  electric  current.    This  appliance  is  equipped  with  a  cord  having  a  grounding  wire  with  a 
grounding plug.   
 Set the electrical power supply within the space covered by the decorative chimney.  
 Position the outlet offset so that the power cord will not interfere with the round duct.  
 Make  sure  this  does  not  interfere  with  a  mounting  bracket  fastening  area  or  with  the  decorative 
chimney (where the chimney touches the wall).  
 
INSTALLING THE UNIT   
 
 
WARNING
:      WHEN  CUTTING  OR  DRILLING  INTO  CEILING,  DO  NOT  DAMAGE  ELECTRICAL  WIRING  AND 
OTHER HIDDEN UTILITIES. WHEN BUILDING FRAMEWORK, ALWAYS FOLLOW ALL APPLICABLE CONSTRUCTION 
CODES AND STANDARDS.  
 
 
IMPORTANT
:  Make sure that holes locations are leveled and correctly centered (this installation instruction 
applies also to concrete).  
 
 
WARNING
:  AT  LEAST  TWO  (2)  PEOPLE  ARE  REQUIRED  TO  LIFT  AND  POSITION  THE  HOOD  ONTO  THE 
MOUNTING SCREWS.  
 
 
WARNING
:  BE CAREFUL WHEN INSTALLING THE DECORATIVE CHIMNEY AND HOOD. THEY MAY HAVE SHARP 
EDGES.  WE RECOMMEND WEARING GLOVES.  
 
 
CAUTION
:  DO NOT REMOVE THE PROTECTIVE PLASTIC FILM COVERING THE DECORATIVE CHIMNEY AT THIS  
 
STAGE.   
 
  
  
 
22
A MINIMUM OF 
28''to 30'' ABOVE 
COOKING SURFACE 
 
IS REQUIRED
 
STANDARD 36" 
 
 
HIGH RANGE
  OR 
 
LOWER CABINETS