PROBLEM
LCD
shows "ER 3"
LCD
shows "ER 4"
Troubleshooting (2-2)
PROBLEM
LCD
shows "ER 5"
LCD
shows "ER 6"
LCD
shows "ER 7"
LCD
shows "ER 8"
LCD
shows "ER A"
No repsonse
when you
press button or
load battery
10. Maintenance
01
02
03 If this monitor is stored near freezing, allow it
12
M-WBPM110-006.indd 12
M-WBPM110-006.indd 12
POSSIBLE CAUSE SOLUTION
Pneumatic sys-
tem blocked
during inflation
Pneumatic sys-
tem leakage
during inflation
POSSIBLE CAUSE SOLUTION
Cuff pressure
above 300mmHg
More than 160
seconds with
cuff pressure
above 15 mmHg
Inner Mem-
ory error
Device parame-
ter checking error
Pressure sensor
parameter error
Incorrect oper-
ation or strong
electromagnet-
ic interference
Do not drop this monitor or subject it to
strong impact.
Avoid high temperature and solarization. Do
not immerse the monitor in water as this will
result in damage to the monitor.
to acclimate to room temperature before use.
04
The monitor requires 6 hours to warm from
Connect the cuff
the minimum storage temperature between
correctly and
uses until the monitor is ready for its INTEND-
try again. If the
ED USE when the ambient temperature is 20°C.
monitor is still
05 The monitor requires 6 hours to cool from the
abnormal, please
maximum storage temperature between uses
contact the lo-
cal distributor
until the the monitor is ready for its INTEND-
or the factory
ED USE when the ambient temperature is 20°C.
06
Do not attempt to disassemble this monitor.
07 If you do not use the monitor for a long time,
please remove the batteries.
08 It is recommended the performance should be
Measure again
checked every 2 years or after repair. Please
after five min-
contact the service center.
utes. If the
09 Clean the monitor with a dry, soft cloth or a soft
monitor is still
abnormal, please
cloth squeezed well after moistened with water,
contact the lo-
diluted disinfectant alcohol, or diluted detergent.
cal distributor
10 No component can be maintained by user in the
or the factory
monitor. The circuit diagrams, component part
lists, descriptions, calibration instructions, or
other information which will assist the user's
appropriately qualified technical personnel to
repair those parts of equipment which are des-
ignated repairably can be supplied.
Take out bat-
teries for five
11 The monitor can maintain the safety and perfor-
minutes, and
mance characteristics for a minimum of 10,000
then reinstall
measurements or three years, and the cuff in-
all batteries
tegrity is maintained after 1,000 open–close
cycles of the closure.
12 It is recommended the cuff should be disinfect-
ed 2 times every week if needed (For example, in
hospital or in clinique). Wipe the inner side (the
side contacts skin) of the cuff by a soft cloth
squeezed after moistened with Ethyl alcohol
(75-90%), then dry the cuff by airing.
13 Not servicing/maintenance while the mon-
itor is in use.
11. Exp
The follo
tions for
SYMBOL
Warning
14/10/2021 11:33:21
14/10/2021 11:33:21