9 WARRANTY CONDITIONS
Vasco hereby declares to guarantee the Vasco D60 for two years from the date
of purchase. The invoice date of the installation company is proof of the purchase
date. If there is no invoice available, the production date will be the purchase date.
The warranty consists only of replacing the ventilator and electronic printed board
by Vasco free of charge. There is no additional warranty period for repairs.
The warranty does not entail:
•
Assembly and disassembly costs
•
Defects, which, in our opinion, are the result of improper handling, negligence
or accidents
•
Defects that are the result of handling or repairs by third parties without our
permission
•
Defects that are the result of irregular and/or unprofessional maintenance
•
Defects that are the result of using the unit in a non-suitable environment
The warranty is void if the ventilation unit is used under the aforementioned
conditions. The installer should contact Vasco for return shipment of defective
components. The installer will receive a warranty return number. The defective
components must be dispatched to Vasco stating this return number.
Kruishoefstraat 50
B-3650 Dilsen
T. +32 (0)89 79 04 11
F. +32 (0)89 79 05 00
info@vasco.eu
www.vasco.eu
MANUFACTURER'S DECLARATION
EU declaration of conformity (low voltage directive 2006/95/EC)
This ventilation unit, type D60, is manufactured by Vasco, Kruishoefstraat 50,
B -3650 Dilsen, Belgium, and carries the CE label. We declare entirely under
our own responsibility that the Vasco D60 unit to which this declaration refers,
complies with the low voltage directive 2006/95/EC, EMC directive 2004/108/
EC, the ROHS directive and directive 2009/125/EC.
Vasco Group nv
Dilsen, België, augustus 2017
P. Nijs, CEO
20 WARRANTY CONDITIONS / MANUFACTURER'S DECLARATION
VENTILATION DECENTRAL
D60
Type aanduiding
Specific energy consumption (SEC)
-39,32
Residential ventilation unit (RVU)
RVU
Non-residential ventilation unit (NRVU
One-directional ventilation unit (OVU)
BVU
Bi-directional ventilation unit (BVU)
Drive type
Variable
Heat recovery system type
Recuperative
Recuperative
Thermal yield of heat recovery
86%
Maximum flow rate
60
Electrical input capacity
10
Noise capacity level
46
Reference flow rate
0,0117
Reference pressure difference
0
Specific power input (SPI)
0,152
Regulation factor
1
Maximum percentages of internal leaks
3,6
Maximum percentages of external leaks
9
LED on the included RF switch that lights up orange twice (after
operation) when the filters should be replaced. Periodically
Place and description of the visual warning
replacing the air filters is important for the optimal functioning
signal for frequently replacing the filters
of the ventilation unit. Not replacing the air filter has an impact
on the yield and the energy efficiency of the device.
Installation instructions for installing
regulated suction grids in the façade for
natural air supply
Internet address for disassembly
instructions
The airflow sensitivity to pressure
8,3
variations at + 20Pa and – 20 Pa
The indoor/outdoor air tightness
0
Annual electricity consumption (AEC)
236
Annual heat saved (AHS)
4454
"moderate climate"
Annual heat saved (AHS) "warm climate"
2014
Annual heat saved (AHS) "cold climate"
8714
D60
D60
D60
+1 Sensor
+1 Sensor
-39,72
-43,64
-43,88
[kWh/(m².a)]
RVU
RVU
RVU
RVU/NRVU
BVU
BVU
BVU
OVU/BVU
Variable
Variable
Variable
Variable / Various speeds
Recuperative
Recuperative
Recuperative / Regenerative
87%
86%
87%
%
80
60
80
[m³/h]
16
10
16
[W]
50
46
50
[dB(A)]
0,0156
0,0117
0,0156
[m³/s]
0
0
0
[Pa]
0,150
0,152
0,150
[W/(m³/h)]
1
0,65
0,65
1 / 0,95 / 0,85 / 0,65
2,7
3,6
2,7
[%]
6,75
9
6,75
[%]
N/A
www.vasco.eu
8,1
8,3
8,1
[%]
0
0
0
[m
3
/h]
233
126
124
[kWhelek/a]
4486
4611
4631
[kWhpe/a]
2029
2085
2094
[kWhpe/a]
8776
9019
9060
[kWhpe/a]
PRODUCTBLAD 21