Led Indicators - tbs electronics Omnicharge DC OCD12/12-50 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Please be aware that in this always on mode, the charger will continue to draw a small
current (< 35mA) from the input battery, even when the turn on input voltage condition has
not been met. This could result in a discharged input battery if allowed for an extended
amount of time.
3.4

LED indicators

The Omnicharge DC units are equipped with individual LEDs for the input- and the output
side. Please see the image below for the location of these LEDs:
The table below explains all available LED conditions:
LED
Status
Input LED
Off
Flashing orange
Continuous green
Flashing red
Output LED
Off
Flashing green
Continuous green
Flashing red
!
CAUTION
Explanation
Charger off
Input voltage too low or turn on delay not
expired yet
All input conditions are OK for charging
Error (see LED error table below)
Charger off, or charging still blocked by
input conditions not being met
Charging in progress
Charging finished (Float stage)
Error (see LED error table below)
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Omnicharge dc ocd12/24-30

Table des Matières