Whirlpool WEE750H0H Instructions D'installation page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Use a Phillips screwdriver to connect the green ground wire
from the power supply cord to the range with the ground-
link screw and ground-link section. The ground wire must be
attached over the ground-link section.
5. Use 3/8" (9.5 mm) nut driver to connect the neutral (white)
wire to the center terminal block post with one of the 10-32
hex nuts.
A
B
C
A. 10-32 hex nut
B. Ground-link screw
C. Line 2 (red) wire
6. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
7. Firmly tighten hex nuts.
NOTE: For power supply cord replacement, use only a
power cord rated at 250 volts minimum, 40- or 50-amps,
that is marked for use with nominal 1
connection opening, with ring terminals and marked for use
with ranges.
8. Tighten strain relief screws.
IMPORTANT: Verify the tightness of the hex nuts.
9. Replace lower access cover.
12
F
E
D
D. Green ground wire
E. Neutral (white) wire
F. Line 1 (black) wire
/
" (3.5 cm) diameter
3
8
Install Using Direct Wire
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Direct Wire Strain Relief
1. Disconnect power.
2. Remove the lower access cover screws located on the back
of the range. Pull the bottom of the cover toward you and out
to remove cover from range.
A. Mounting tabs (3)
B. Lower access cover
C. Screws (2)
3. Depending on your model, remove plastic tag holding three
10-32 hex nuts from the middle post of the terminal block.
Remove the top 10-32 hex nut from each of the 3 terminal
blocks and set aside.
Remove the top 10-32 hex nut from each of the 3 terminal
blocks and set aside.
A
B
C
OR

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ywee750h0hWeea25h0hYweea25h0h

Table des Matières