Safety Precaution; Installation Instructions - V-ZUG DW-N6 Manuel D'utilisation

Masquer les pouces Voir aussi pour DW-N6:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
GENERAL
Carefully read the following important information regarding
installation safety and maintenance. Keep this information
booklet accessible for further consultations.
The appliance has been designed for use in the ducting ver-
sion (air exhaust to the outside – Fig.1B) or filtering version (air
circulation on the inside – Fig.1A).

SAFETY PRECAUTION

1. Take care when the cooker hood is operating simultaneously
with an open fireplace or burner that depend on the air in the
environment and are supplied by other than electrical energy,
as the cooker hood removes the air from the environment
which a burner or fireplace need for combustion. The negative
pressure in the environment must not exceed 4Pa (4x10
Provide adequate ventilation in the environment for a safe
operation of the cooker hood. Follow the local laws applicable
for external air evacuation.
Before connecting the model to the electricity network:
- Control the data plate (positioned inside the appliance)
to ascertain that the voltage and power correspond to the
network and the socket is suitable. If in doubt ask a qualified
electrician.
- If the power supply cable is damaged, it must be replaced with
another cable or a special assembly, which may be obtained
direct from the manufacturer or from the Technical Assistance
Centre.
2. Warning!
In certain circumstances electrical appliances may be a
danger hazard.
A) Do not check the status of the filters while the cooker
hood is operating.
B) Do not touch bulbs or adjacent areas, during or straight
after prolonged use of the lighting installation.
C) Flambè cooking is prohibited underneath the cooker
hood.
D) Avoid free flame, as it is damaging for the filters and a
fire hazard.
E) Constantly check food frying to avoid that the
overheated oil may become a fire hazard.
F) Disconnect the electrical plug prior to any maintenance.
G) This appliance is not intended for use by young children
or infirm persons without supervision.
H) Young children should be supervised to ensure they do
not play with the appliance.
I) There shall be adequate ventilation of the room when
the rangehood is used at the same time as appliances
burning gas or other fuels.
L) There is a risk of fire if cleaning is not carried out in
accordance with the instructions.
This appliance conforms to the European Directive EC/2002/96,
Waste Electrical and Electronic Equipment (WEEE).
By making sure that this appliance is disposed of in a suitable
manner, the user is helping to prevent potential damage to
the environment or to public health.
ENGLISH
The symbol on the product or on the accompanying
paperwork indicates that the appliance should not be
treated as domestic waste, but should be delivered to
a suitable electric and electronic appliance recycling
collection point. Follow local guidelines when disposing of
waste. For more information on the treatment, re-use and
recycling of this product, please contact your local authority,
domestic waste collection service or the shop where the ap-
pliance was purchased.

INSTALLATION INSTRUCTIONS

Assembly and electrical connections must be carried out
by specialised personnel.
• Electric Connection
The appliance has been manufactured as a class II, therefore
-5
bar).
no earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load indi-
cated on the description label. Where a plug is provided, the
cooker hood must be installed in order that the plug is easily
accessible.
An omnipolar switch with a minimum opening of 3mm be-
tween contacts, in line with the electrical load and local stan-
dards, must be placed between the appliance and the network
in the case of direct connection to the electrical network.
Warning:
When connecting the appliance to the electricity supply, make
sure that the mains socket has an earth connection.
After fitting the ducted cooker hood, make sure that the
electrical plug is in a position where it can be accessed
easily.
If the appliance is connected directly to the electricity supply,
an omnipolar switch with a minimum contact opening of
3 mm must be placed in between the two; its size must be
suitable for the load required and it must comply with current
legislation.
• The minimum distance between the support surfaces of
the cooking pots on the cooker top and the lowest part of
the cooker hood must be at least 65 cm. If a connection tube
composed of two parts is used, the upper part must be placed
outside the lower part. Do not connect the cooker hood
exhaust to the same conductor used to circulate hot air or for
evacuating fumes from other appliances generated by other
than an electrical source.
Before proceeding with the assembly operations, remove the
anti-grease filter(s) (Fig.6) so that the unit is easier to handle.
In the case of assembly of the appliance in the suction version
prepare the hole for evacuation of the air.
• We recommend the use of an air exhaust pipe with a
diameter of 150. If a pipe with a smaller diameter is used, the
efficiency of the product may be reduced and its operation
may become noisier.
- 12 -
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dw-n9

Table des Matières