GENERAL
Carefully read the following important information regarding
installation safety and maintenance.
Keep this information booklet accessible for further consulta-
tions. The appliance has been designed for use in the ducting
version (air exhaust to the outside – Fig.1B), filtering version
(air circulation on the inside – Fig.1A) or with external mo-
tor (Fig.1C).

SAFETY PRECAUTION

1. Take care when the cooker hood is operating simultane-
ously with an open fireplace or burner that depend on the air
in the environment and are supplied by other than electrical
energy, as the cooker hood removes the air from the environ-
ment which a burner or fireplace need for combustion.
The negative pressure in the environment must not exceed
-5
4Pa (4 x 10
bar).
Provide adequate ventilation in the environment for a safe
operation of the cooker hood. Follow the local laws applicable
for external air evacuation.
Before connecting the model to the electricity network:
- Control the data plate (positioned inside the appliance)
to ascertain that the voltage and power correspond to the
network and the socket is suitable. If in doubt ask a qualified
electrician.
- If the power supply cable is damaged, it must be replaced
with another cable or a special assembly, which may be
obtained direct from the manufacturer or from the Technical
Assistance Centre.
2. Warning!
In certain circumstances electrical appliances may be a
danger hazard.
A) Do not check the status of the filters while the cooker
hood is operating.
B) Do not touch bulbs or adjacent areas, during or straight
after prolonged use of the lighting installation.
C) Flambè cooking is prohibited underneath the cooker
hood.
D) Avoid free flame, as it is damaging for the filters and a
fire hazard.
E) Constantly check food frying to avoid that the over-
heated oil may become a fire hazard.
F) Disconnect the electrical plug prior to any maintenance.
G) This appliance is not intended for use by young children
or infirm persons without supervision.
H) Young children should be supervised to ensure they do
not play with the appliance
I) There shall be adequate ventilation of the room when
the rangehood is used at the same time as appliances
burning gas or other fuels.
L) There is a risk of fire if cleaning is not carried out in
accordance with the instructions.
This appliance conforms to the European Directive EC/2002/96,
Waste Electrical and Electronic Equipment (WEEE).
By making sure that this appliance is disposed of in a suitable
manner, the user is helping to prevent potential damage to
the environment or to public health.
ENGLISH
The symbol on the product or on the accompanying
paperwork indicates that the appliance should not be
treated as domestic waste, but should be delivered to
a suitable electric and electronic appliance recycling
collection point. Follow local guidelines when disposing of
waste. For more information on the treatment, re-use and
recycling of this product, please contact your local authority,
domestic waste collection service or the shop where the ap-
pliance was purchased.

INSTALLATION INSTRUCTIONS

Assembly and electrical connections must be carried out
by specialised personnel.
• Electric Connection:
This is a class I, appliance and must therefore be connected
to an effiecient earthing system.
- The appliance must be connected to the electricity supply
as follows:
BROWN = L line
BLUE = N neutral
YELLOW/GREEN =
The neutral wire must be connected to the terminal with the
N symbol while the YELLOW/GREEN, wire must be connected
to the terminal by the earth symbol
When connecting the appliance to the electricity supply,
make sure that the mains socket has an earth connection.
After fitting the ducted cooker hood, make sure that the
electrical plug is in a position where it can be accessed easily.
If the appliance is connected directly to the electricity sup-
ply, an omnipolar switch with a minimum contact opening
of 3 mm must be placed in between the two; its size must
be suitable for the load required and it must comply with
current legislation.
• The minimum distance between the support surfaces of
the cooking pots on the cooker top and the lowest part of
the cooker hood must be at least 65 cm. If a connection
tube composed of two parts is used, the upper part must be
placed outside the lower part. Do not connect the cooker
hood exhaust to the same conductor used to circulate hot air
or for evacuating fumes from other appliances generated by
other than an electrical source. Before proceeding with the
assembly operations, remove the anti-grease filter(s) (Fig.15)
so that the unit is easier to handle.
• We recommend the use of an air exhaust tube which has the
same diameter as the air exhaust outlet hole. If a pipe with
a smaller diameter is used, the efficiency of the product may
be reduced and its operation may become noisier.
In the case of assembly of the appliance in the suction version
prepare the hole for evacuation of the air.
Attention!
- Before installing the appliance, fix the electrical box D.
- Lift the electrical box and follow phases 1-2-3 indicated in
figure 2.
- Position the bracket in correspondence with the 3 screws G
already set up on the container and screw them is indicated
in phase 4 - figure 2.
- Fix the air exhaust pipe H (not included) on the air outlet
- 19 -