• AC output
Model
Rated output apparent power [VA]
Max. output apparent power [VA]
Nominal AC voltage [a.c. V]
Nominal AC frequency [Hz]
Rated output current [a.c. A]*
Max. output continuous current [a.c. A]
Current (inrush) [a.c. A]
THDi, rated power
Power factor range
Feed-in phase
Maximum output fault current [a.c. A]
Maximum output overcurrent
protection [a.c. A]
Short circuit current [a.c. A]
Model
Rated output apparent power [VA]
Max. output apparent power [VA]
Nominal AC voltage [a.c. V]
Nominal AC frequency [Hz]
Rated output current [a.c. A]*
Max. output continuous current [a.c. A]
Current (inrush) [a.c. A]
THDi, rated power
Power factor range
Feed-in phase
Maximum output fault current [a.c. A]
Maximum output overcurrent
protection [a.c. A]
Short circuit current [a.c. A]
* If there are two data for this parameter, each data corresponds to the corresponding voltage.
X3-MIC-
X3-MIC-
3K-G2
4K-G2
3000
4000
3300
4400
3~/N/PE, 220/380, 230/400; 3~/PE, 380, 400
4.6, 4.4
6.1, 5.8
4.8
6.4
X3-MIC-
X3-MIC-
10KW-G2
12K-G2
10000
12000
10000
13200
3~/N/PE, 220/380, 230/400;
3~/PE, 380, 400
15.2, 14.5
18.2, 17.4
16.0
19.1
X3-MIC-
X3-MIC-
5K-G2
6K-G2
5000
6000
5500
6600
50/60 (±5)
7.6, 7.3
9.1, 8.7
8.0
9.6
30 (20 μs)
<3%
0.8 leading-0.8 lagging
Three-phase
44
39
30
X3-MIC-
X3-MIC-
15K-G2
5K-G2-LV
15000
5000
15000
5500
3~/N/PE, 127/220;
50/60 (±5)
22.7, 21.8
13.2
22.7
14.5
30 (20 μs)
<3%
0.8 leading-0.8 lagging
Three-phase
44
39
30
X3-MIC-
X3-MIC-
8K-G2
10K-G2
8000
10000
8800
11000
12.2, 11.6
15.2, 14.5
12.8
16.0
X3-MIC-
X3-MIC-
6K-G2-LV
8K-G2-LV
6000
8000
6600
8800
3~/PE, 220
15.8
21
17.4
23.1
67

Publicité