3. Technical data and intended use
Case, bezel ring:
Window:
Installation
Nominal position per EN 837-3 / 9.6.6 Figure 7: 90° ( ⊥ )
Process connection: lower mount (LM)
In order to ensure that, with both Models 53X.31 ... 34, pressure can be
safely and reliably vented through the case back, a distance of at least
25 mm must be left free behind the case!
In order to avoid any additional heating, the instruments must not be
exposed to direct solar irradiation while in operation!
With filled versions the ventilating valve (pressure ranges ≤ 10 bar) at the top
of the case must be opened prior to commissioning!
Permissible vibration load at the mounting point
The instruments should always be installed in locations free from vibration.
If necessary, it is possible to isolate the instrument from the mounting point
by installing a flexible connection line between the measuring point and the
pressure gauge and mounting the instrument on a suitable bracket.
If this is not possible, the following limit values must not be exceeded:
Dry gauges:
(Model 532)
Liquid-filled gauges:
(Model 533)
The liquid filling has to be checked on a regular basis.
The liquid level must not drop below 75 % of the gauge diameter.
WIKA Operating Instructions pressure gauges Model 5 per ATEX
Stainless steel
(Model 53X.3X: with blow-out back)
Laminated safety glass
Frequency range < 150 Hz
Acceleration < 0.7 g (7 m/s
Frequency range < 150 Hz
Acceleration < 4 g (40 m/s