Télécharger Imprimer la page

Panasonic CS-E9NKUAW Instructions D'utilisation page 9

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING
The unit stops and the TIMER indicator blinks.
The unit stops and the TIMER indicator blinks.
Use remote control to retrieve error code.
1
Press for 5 seconds.
3
Press for 5 seconds to
quit checking.
• For certain errors, you may restart the unit for limited operation with 4 beeps when operation starts.
Diagnostic
Abnormality/Protection control
display
H 00
No memory of failure
H 11
Indoor/outdoor abnormal communication
H 12
Indoor unit capacity unmatched
H 14
Indoor intake air temperature sensor
abnormality
H 15
Compressor temperature sensor
abnormality
H 16
Outdoor current transformer (CT)
abnormality
H 19
Indoor fan motor mechanism lock
H 23
Indoor heat exchanger temperature sensor
abnormality
H 24
Indoor heat exchanger temperature sensor
2 abnormality
H 27
Outdoor air temperature sensor
abnormality
H 28
Outdoor heat exchanger temperature
sensor 1 abnormality
H 30
Outdoor discharge pipe temperature
sensor abnormality
H 32
Outdoor heat exchanger temperature
sensor 2 abnormality
H 33
Indoor/outdoor misconnection abnormality
H 36
Outdoor gas pipe temperature sensor
abnormality
*1 For cooling only model, it is the indication when indoor heat exchanger sensor or indoor air intake sensor has abnormality.
All manuals and user guides at all-guides.com
TIMER
ON
SET
1
2
3
OFF
CANCEL
AC
RC
SET CHECK CLOCK
RESET
Diagnostic
display
2
Press until you hear beep sound, then write
down the error code.
4
Turn the unit off and reveal the error code to
authorised dealer
Abnormality/Protection control
H 37
Outdoor liquid pipe temperature sensor
abnormality
H 38
Indoor/outdoor mismatch (brand code)
H 39
Abnormal indoor operating unit or standby
units
H 64
Outdoor high pressure sensor abnormality
H 97
Outdoor fan motor mechanism lock
H 98
Indoor high pressure protection
H 99
Indoor operating unit freeze protection
F 11
4-way valve switching abnormality *1
F 17
Indoor standby units freezing abnormality
F 90
Power factor correction (PFC) circuit
protection
F 91
Refrigeration cycle abnormality
F 93
Compressor abnormal revolution
F 94
Compressor discharge pressure overshoot
protection
F 95
Outdoor cooling high pressure protection
F 96
Power transistor module overheating
protection
F 97
Compressor overheating protection
F 98
Total running current protection
F 99
Outdoor direct current (DC) peak detection
9

Publicité

loading

Ce manuel est également adapté pour:

Cs-e12nkuawCu-e9nkuaCu-e12nkuaCu-2e18nbuCu-5e36qbu