In addition to all the current process parameters, the relevant current phase, the cycle
sequence and the cycle number will be displayed beside the mode. The relevant informa-
tion will be displayed during a charge phase and the reverse sequence of a procedure.
7.2
EQUAlIzER DISPlAy
"DEC" or "INC" button allows the individual voltage of each cell voltage to be viewed. The
illustration shows an illustration for a 3 cell battery. The individual cells of the battery are
well balanced. The voltage difference is 2 mV.
The voltage condition of the single cells can be displayed in the upper part of the screen.
Additionally, the minimum and maximum battery cell voltages are graphically shown. The
illustration above shows such a screen for a 3 cell LiPo battery.
The middle voltage range will be calculated and displayed in the left hand side of the upper
line (3S = 12.385 V). The relevant cell voltages of the highlighted cells will be shown to the
right. The display is made with a resolution of 1 mV.
In the lower line, the voltage difference between the maximum and minimum battery pack
cell voltages is shown.
This style of display allows one to have a quick and precise summary of the voltage con-
dition of the single cells.
Operating Instructions
Power Peak ® Twin EQ-BID
During the running of a cycle operation, the screen dis-
play looks similar to this also. "CYCLE" is shown when
checking the battery. The illustration shows the upper part
of the screen during a cycle process when charging a
battery.
When charging as well as discharging a lithium battery,
the individual cell voltage can be seen in the display of the
Power Peak ® Twin EQ-BID. The pre-requisite is that the
Lithium battery is connected to the charger by the voltage
sensor lead. In this screen, a summary of the balance
condition of the complete battery is posiible. Pressing the
22