1.
Remove terminal block cover plate located on the right end of the appliance. Keep screws
for reassembly.
2.
Install a wire strain relief bushing into the cover plate.
3.
Terminate type NM-B wire to the terminal block, ensure connections are secure, and tighten
the strain relief. Use 3/32 slotted head screwdriver, or equivalent, to depress the spring-
loaded terminals for the conductors.
4.
Replace terminal block cover plate and retaining screws.
2.7 FIREPLACE REPAIR GUIDES