a) Type of insulation in accordance with EN 61010-1 ................................................................. double
b) Measurement category in accordance with EN 61010-1 .................................................... III 600 V
c) Ingress protection in accordance with EN 60529 ...................................................................... IP42
d) Frequency range .............................................................................................................10...70 Hz
e) Nominal phase-to-phase voltage range:
▪
.................................................................................................................... 160...690 V AC
▪
...................................................................................................................... 35...690 V AC
f)
Maximum phase-to-phase working voltage ....................................................................... 760 V AC
g) Measurement current (per each phase) .............................................................................. <3.5 mA
h) Working temperature ....................................................................................................... -10...45ºC
i)
Storage temperature ...................................................................................................... -20...+60ºC
Acceptable working humidity ............................................................................................. 20...80%
j)
k) Tester power supply ................................................................ from the tested electrical installation
l)
Dimensions .......................................................................................................... 130 x 72 x 31 mm
m) Mass of the tester (with leads) ............................................................................................ ca 340 g
The device does not have the character of a standard and therefore is not subject to
calibration. The proper form of control for this type of instrument is checking.
The manufacturer of the device and provider of guarantee and post-guarantee service:
NOTE!
Service repairs must be performed only by the manufacturer.
10
6
Technical data
7
Manufacturer
SONEL S.A.
Wokulskiego 11
58-100 Świdnica
Poland
tel. +48 74 884 10 53 (Customer Service)
e-mail:
customerservice@sonel.com
web page:
www.sonel.com
TKF-12 ● TKF-12L – USER MANUAL