Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Programmable
Digital
Thermostat
Product
Information
Quick reference to controls
Screen
Set: Press to set time/
day/schedule.
Hold: Press to
override programmed
temperature control.
Run: Press to resume
program schedule.
E.M. Heat Heat Off Cool
Quick reference to display screen
Setpoint indicator
Low battery warning
Appears when the
setpoint temperature is
displayed.
6 : 30
Current day/time
We
Current program period
Wake/Leave/
Wake
Return/Sleep
System status
Cool On: Cooling system is on.
Heat On: Heating system is on.
Aux On: Auxiliary heat is on.
(Only for heat pumps with this capability [select models only].)
When Heat On or Cool On is flashing, compressor protection is engaged.
Set the time and day
Press SET, then adjust time.
Set Time
6 : 30
am
Press SET, then select current day.
Set
Day
We
Select the system setting
Fan
E.M. Heat Heat Off Cool
Auto On
Set SYSTEM switch to control the
heating or cooling system.
Lit for 12 seconds when you press any button.
Fan
Auto On
M32781
Temperature
The ambient
Lo
(measured)
Batt
temperature is
75
Set
normally displayed.
am
To view the setpoint
temperature,
press the Up or
Heat
Down button
On
once. The setpoint
temperature will
M32701
appear for five seconds.
1.
Press the SET button, then press s or
t to set the clock time.
2.
Press the SET button, then press s or
t to select the day of the week.
3.
Press RUN to save & exit.
M32702
Note: If the clock flashes, the thermostat
will follow your settings for the Monday
"Wake" time period until you reset the time
and day.
M32703
The SYSTEM switch can be set to control
your heating or cooling system, depending
on the season.
Cool: Cooling system control.
Off: All systems are off.
Heat: Heating system control.
Em Heat: Emergency & Auxiliary
Heat control. Compressor is locked
out. (Select models only.)
M32781
PRO
2000
Select the fan setting
Temperature
adjustment
E.M. Heat Heat Off Cool
Energy saving settings for maximum cost
savings
This thermostat is pre-set to use energy saving program settings. We recommend
these settings, since they can reduce your heating/cooling expenses. (See next page
to adjust times and temperatures of each time period.)
Wake
(6:00 am)
Leave
(8:00 am)
Return
(6:00 pm)
Sleep
(10:00 pm)
To adjust program schedules
1.
Press SET until Set Schedule is
displayed.
2.
Press s or t to set your weekday
Wake time (Mo-Fr), then press SET.
3.
Press s or t to set the
temperature for this time period,
then press SET.
4.
Set time and temperature for the
next time period (Leave). Repeat
steps 2 and 3 for each weekday
time period.
5.
Press SET to set weekend time periods (Sa & Su), then press RUN to save & exit.
Note: Make sure the thermostat is set to the system you want to program (Heat or
Cool).
Product Manuals
Search online for Resideo 69-2608EFS for the Owner's Guide.
CAUTION
Equipment damage hazard
To prevent possible compressor damage, do not
operate cooling system when outdoor temperature is
below 50°F (10°C).
Series
Set the FAN switch to Auto or On.
In "Auto" mode (the most commonly
used setting), the fan runs only when the
heating or cooling system is on.
If set to "On," the fan runs continuously.
Set FAN switch to choose whether the fan
runs continuously or only as needed.
Fan
Auto On
M32781
Heat
Cool
(Mon-Fri)
(Mon-Fri)
(Sat-Sun)
°
°
70
78
70
°
°
62
85
62
°
°
70
78
70
°
°
62
82
62
Press SET 3 times,
then adjust time.
Heat
Cool
(Sat-Sun)
°
°
78
°
°
85
°
°
78
°
°
82
6 : 30
75
Set
am
Mo Tu We Th Fr
Wake
Set Schedule
M32706
Press SET, then set
desired temperature.
33-00304EFS-05

Publicité

loading

Sommaire des Matières pour Honeywell TH2110DH1002/U

  • Page 1 Programmable Digital 2000 Thermostat Series Product Information Quick reference to controls Select the fan setting Screen Lit for 12 seconds when you press any button. Set the FAN switch to Auto or On. In “Auto” mode (the most commonly Set: Press to set time/ used setting), the fan runs only when the day/schedule.
  • Page 2 Thermostat numérique 2000 programmable Information Série produit Coup d’oeil rapide sur les commandes Sélectionner le réglage du ventilateur Écran S’allume pendant 12 secondes lorsque n’importe Régler le sélecteur du ventilateur FAN à Auto ou à On. quel bouton est appuyé. Set : Appuyer sur cette touche pour En mode de fonctionnement automatique...
  • Page 3 Termostato digital 2000 programable Información de Serie producto Rápida referencia de los controles Seleccione la configuración del ventilador Mueva el interruptor “FAN” hasta la Pantalla Se ilumina durante 12 segundos cuando se posición “Auto” u “On”. presiona cualquier botón. “Set” (configuración): En el modo “Auto”, la configuración usada Presione este botón para configurar la hora, el día...
  • Page 4 33-00304EFS—05 M.S. Rev. 07-20 | Printed in United States This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN © 2020 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved.

Ce manuel est également adapté pour:

Pro 2000 serie