Télécharger Imprimer la page

Toshiba RAS-10SKV Serie Mode D'emploi page 3

Masquer les pouces Voir aussi pour RAS-10SKV Serie:

Publicité

Les langues disponibles

Les langues disponibles

11
TEMPORARY OPERATION
In case of the misplaced or discharged remote control
• Pressing the RESET button, the unit can start or
stop without using the remote control.
• Operation mode is set on AUTOMATIC operation,
preset temperature is 24°C and fan operation is
automatic speed.
12
TIMER OPERATION
Setting the ON Timer
1
Press
ON
: Set the desired ON timer.
2
SET
Press
: Set the timer.
3
CLR
Press
: Cancel the timer.
Daily timer allows the user to set both the ON & OFF timers and will be
activated on a daily basis.
Setting Daily Timer
1
ON
Press
: Set the ON timer.
2
OFF
Press
: Set the OFF timer.
• During the daily timer is activating, both arrows ( , ) are indicated.
Note:
• Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur.
• The setting will be saved for the next same operation.
13
PRESET OPERATION
Set your preferred operation for future use. The setting will be memorized by
the unit for future operation (except airfl ow direction).
1. Select your preferred operation.
PRESET
2. Press and hold
for 3 seconds to memorize the setting.
The P mark displays.
PRESET
3. Press
: Operate the preset operation.
14
AUTO RESTART OPERATION
To automatically restart the conditioner after the power failure (Power of the
unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for
5 seconds)
• Do not operate ON timer and OFF timer.
2. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
15
QUIET OPERATION
To operate at super low fan speed for quiet operation (except in DRY mode)
QUIET
Press
: Start and stop the operation.
Note: Under certain conditions, QUIET operation may not provide adequate
cooling or heating due to low sound features.
16
COMFORT SLEEP OPERATION
To save energy while sleeping, automatically control air fl ow and
automatically turn OFF.
COMFORT
SLEEP
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
17
SLEEP TIMER OPERATION
To start the sleep timer (OFF timer) operation
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
SLEEP
1110250165.indb 3
1110250165.indb 3
Setting the OFF Timer
Press
OFF
: Set the desired OFF timer.
SET
Press
: Set the timer.
CLR
Press
: Cancel the timer.
3
Press
SET
.
SET
Press
button during the
4
( or ) mark fl ashing.
18
MAINTENANCE
Firstly, turn off the circuit breaker.
Filter Reset (Some models only)
FILTER lamp lights on; the fi lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit or the FILTER
button on the remote control.
Indoor Unit and Remote Control
• Clean the indoor unit and the remote control with a wet cloth when
needed.
• No benzine, thinner, polishing powder or chemically-treated duster.
19
SELF CLEANING OPERATION (COOL AND DRY OPERATION ONLY)
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during "Cool" or "Dry" mode, the fan will
continue to run for other 20 minutes, then it will turn off automatically.
This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
Note:
• SELF CLEANING operation is default setting from factory.
• To cancel this function, please contact the supplying retail dealership.
20
OPERATION AND PERFORMANCE
1. Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the heating
operation starts.
3. Warm air control: When the room temperature reaches the set
temperature, the fan speed is automatically reduced and the outdoor
unit will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released into
the room. When the outdoor temperature is too low, use another
recommended heating apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit
where it will not be subjected to snow drifts, accumulation of leaves or
other seasonal debris.
7. Some minor cracking sound may occur when unit operating. This is
normal because the cracking sound may be caused by expansion/
contraction of plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Outdoor Temperature
Operation
Heating
–15°C ~ 24°C
Cooling
–10°C ~ 46°C
Dry
–10°C ~ 46°C
21
TROUBLESHOOTING (CHECK POINT)
The unit does not operate.
Cooling or Heating is abnormally low.
• The power main switch is
• The fi lters are blocked with dust.
turned off.
• The temperature has been set improperly.
• The circuit breaker is
• The windows or doors are opened.
activated to cut off the power
• The air inlet or outlet of the outdoor
supply.
unit is blocked.
• Stoppage of electric current
• The fan speed is too low.
• ON timer is set.
• The operation mode is FAN or DRY.
22
REMOTE CONTROL A-B SELECTION
To separate using of remote control for each indoor unit in case of 2 air
conditioner are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold CHK
button on the Remote Control by the tip of the
pencil. "00" will be shown on the display.
MODE
during pushing CHK
4. Press
"00" will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized.
Note: 1. Repeat above step to reset Remote
Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.
EN
ES
FR
3 times within 30 seconds.
IT
DE
PT
PL
CZ
CR
HU
NL
GR
Room
Temperature
Less than 28°C
SV
21°C ~ 32°C
17°C ~ 32°C
FI
NO
DK
RO
BG
EE
LV
SK
SI
. "B" will show on the display and
10/27/09 3:58:51 PM
10/27/09 3:58:51 PM

Publicité

loading

Ce manuel est également adapté pour:

Ras-13skv2 serieRas-16skv2 serie