Télécharger Imprimer la page

Lincar Monellina 176AN PLUS Instructions page 30

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3 MAINTENANCE AND CLEANING RESERVED TO USER
IMPORTANT WARNING
Every maintenance and cleaning operations must be done when the stove is light off and
cold.
The stove's conditions must be checked by our qualify staff.
3.1 Cleaning to be carried out by the User
The frequency of the stove cleaning and maintenance is depending from wood quality an
quantity. An high degree of humidity, ash, powder or chemicals adds inside the wood
could increase the necessary cleaning and maintenance operations; so we recommend
again to employ a very high quality of wood.
Foyer Cleaning . To obtain the best performance during stove's functioning, EVERY
DAY it's necessary to clean the foyer grate, empty it from every residuals, clean all the
holes on the bottom and replace it into its place.
External Cleaning. This operation must be done when the stove is cold.
Steel/cast iron parts : use a duster with specific detergent
Windows/Ceramic: Use a sponge with specific detergent than dry the parts with a
dry duster.
Painted parts : Use a duster and neutral soap than dry the parts with duster.
3.2 Ordinary maintenance (by qualify staff)
EVERY YEAR IS RECOMMENDED THE FOLLOWING OPERATIONS
MAINTENANCE:
Complete check up of the stove by qualify staff.
Cleaning of exhaust gas.
To check and eventually to replace of seal..
To check the flue seal.
To check integrity of the glass fire door
We recommend to stipulate a contract with an after-sales service.
We recommend to execute a regular maintenance of the appliance, of the fumes exhaust
ducts and of the chimney. In case of a long time of non utilization of the appliance, before
lighting the appliance, verify that fume exhaust ducts and chimney are not obstructed.
Internal exhaust gas fumes cleaning :
At least one per year or every time it's necessary
The operation should be done by a qualify staff, because the top should be removed
mechanically.
All the necessary equipment should be prepared before operations
a)
Unscrew the frame from the cast iron top.
b)
Unscrew the rest of fixing screws of cast iron top. Remove the top making attention to
the combustion residuals.
c)
Clean the inside stove parts removing every combustion residuals.
d)
Reassemble the stove to proceed to the assembly being repeated the operations in inverse
way.
N.B. In order to assure the correct stove functioning, it is necessary to grant the perfect
seal between the sheet body and the cast iron top removing the silicone residuals. Re-put
new silicone (resisting to temperatures 1000÷1100° C)
IT IT IT IT- - - - GB
GB- - - - FR
FR- - - - ES
GB
GB
FR
FR
30/76
ES- - - - DE
DE mod. 176AN PLUS
ES
ES
DE
DE

Publicité

loading