Installation Instructions for the Véro

General instructions

Preparation

Installation
Repairs
Technical details Véro / Véro 33 / Vérox
General instructions
The Véro is tested in accordance with the international
EN 13240 standardization, and has an extra additional
standardization for optimally environment-friendly
heating devices related to flue gases (Section 15a B-Vg.
Des BmfWA). The stove can be connected to a flue tube
to which several stoves are connected. The flue tube has
a diameter of 150 millimetres.
The heating device must be placed by an acknowledged
installer and according to the installation instructions
given below. The national and local rules and regulations
for placing and using wood-burning stoves are equally
applicable. WANDERS does not give any guarantee
if the Véro is connected or installed incompletely or
incorrectly.
It is not allowed to place the stove in:
• Arcades and corridors accessible to the public.
• Stairwells, except in buildings with no more than 2
dwellings.
• Spaces where highly flammable or explosive materials
Roof slope x larger than 23°
21
21
22
24
24
are used.
• Spaces where an exhaust system is used or where a
mechanical exhaust system is placed, except when
the air supply is taken directly from outside to assure
a hazardless combustion.
Preparation
The chimney flue
Before placing the stove you must observe the following
points:
• If the stove is connected to an existing chimney, you
must first have the chimney professionally cleaned
and checked by a qualified chimney sweep company.
Any cut-off valves or stop valves must be removed.
• The flue tube of the stove must be connected with the
chimney without diversions.
• The underpressure in the chimney must be at least 12
Pa or 0.12 mbar.
• The chimney flue must always end up in outlet area 1
(see the drawing and the table below)
Roof slope x smaller than 23°