Télécharger Imprimer la page

Beninca RI.5E/K/I Livret D'instructions page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

(J2)
SENS_H= Input for optional anti-crash card "DA.AS"
1-2 pin: 24Vdc power supply (1 + ; 2 - )
2-3 pin: n.c. contact input
or for any other n.c. safety device (pneumatic profile, photocells, etc.)
2-3 pin: n.c. contact input;
the activation of the device connected to these terminals causes the stopping or the
reversion movement of the motor.
Note: Pins 2 and 3 must be short-circuited if not in use.
"Select" dip-switch functions
N.B.:
Every change of functions have to be done without electricity.
DSW1
This selects the type of functioning of the P.P. button and Remote control.
Off= "OPEN" - "STOP" - "CLOSE" functioning
On= "OPEN" - "CLOSE" - "OPEN" functioning.
DSW2
This enables or disables the automatic re-closing - "TCA TRIMMER".
Off= Automatic re-closing enabled
On= Automatic re-closing disabled
DSW3
This enables or disables the apartment building function (after the first opening command, the
P.P. button and the Remote control are deactivated).
Off= Apartment building function disabled.
On= Apartment building function enabled.
DSW4
This enables or disables the pre-blinking function.
Off= Pre-blinking disabled.
On= Pre-blinking enabled.
DSW5
This enables or disables the motor starting function.
Off= Motor starting function disabled
On= Motor starting function enabled
DSW6
This selects the type of intervention of the "FTC" input on opening.
Off= No intervention
On= Temporary stop
DSW7
This selects the type of functioning of the "OPEN" input.
Off= Functioning as "OPEN button"
On= Functioning as "PEDESTRIAN button"
DSW8
It enables the activation of the sensor connected to SENS_H during the opening phase.
Off= Enabled in both opening and closing phases.
On= Enabled only in the closing phase.
"By-pass" dip-switch function
The "By-pass" dip-switches allow to exclude the normally closed inputs which are not in use
DSW1
Input Stop
Off= Enabled input
On= Disabled input.
DSW2
Input FTC
Off= Enabled input
On= Disabled input.
DSW3
Input FCA
Off= Enabled input
On= Disabled input.
DSW4
Input FCC
Off= Enabled input
On= Disabled input.
Trimmer functions
TCA
This allows the automatic re-closing time to be adjusted when this is enabled by positioning the
DSW2 Dip-switch on OFF.
Adjustment can be from a minimum of 10 to a maximum of 200 seconds.
The minimum time is obtained by rotating the trimmer completely anticlockwise.
TL
This allows the working time of the automation to be adjusted. If the limit switches fail, the soft-
ware protection will intervene after this time has elapsed. (Add about 4 sec. to the actual stroke
time of the automation).
Adjustment can be from a minimum of 10 to a maximum of 200 seconds.
The minimum time is obtained by rotating the trimmer completely anticlockwise.
7

Publicité

loading