Routine Maintenance
It is recommended that the humidifier pad be replaced once per year. This can be done at the beginning or the
end of the dry season. The humidifier design makes this annual replacement quick and easy, providing one-step
access to the pad.
Bypass:
Pad can be replaced from the side by gripping
1a.
the black handle and pulling out, or from the
front by removing the humidifier's top cover
and rocking the pad forward and out.
Humidifier pad might remove from other side
of humidifier, depending on installation.
2
Remove tray on top of the pad, and wipe free any sediment present within the tray.
2.
Replace the old pad with the new, making sure pad is oriented correctly (see pad box). Wipe free any
3.
sediment present inside the pad frame.
Reseat the tray on top of the pad with the arrows inside the tray pointing
4.
into the humidifier.
Afer pad replacement is complete, remove the bottom cover and press the RESET button to reset the
5.
maintenance timer.
22
All manuals and user guides at all-guides.com
1
25%
MCR29885
Fan:
Pad can be replaced from the front by gripping
1b.
the black handle and pulling out.
into the duct. Then reinsert the frame
MCR29886