3 Maintenance
3.1 Changing filters
In addition to the main filter (pos. 1), the MaxiFil AK also has an Active carbon filter
(pos. 2).
When changing the filter, please observe the following indications in addition to
the information found in the MaxiFil Operating Manual:
o See the item (filter change) in the appendix for an illustrated Quick Start Guide
to change both filter elements.
o See Figure 1 for the sequence in which the filter elements should be
positioned.
A change of the active carbon filter is required if:
o Material which should be separated by the active carbon filter can be clearly
detected at the exhaust opening of the device.
o In any case, the active carbon filter should be changed at the latest along with
the main filter, since at this point, the active carbon filter unit is also saturated.
Figure 1, filter types in the MaxiFil AK
- 11 –
Technical changes and errors excepted.
KEMPER MaxiFil Active Carbon
Appendix to Operating Manual - EN