Note: Make sure that the water inlet hose does
not come loose by movement when installing
the cooler.
When transporting or installing the cooling
unit, cooling fluid may have run into the lines.
In order to ensure that the cooling fluid
has run back, the cooling unit may only be
installed following a pause of 24 hours.
Display:
In the inactive state, the remaining filter capaci-
ty is displayed in.
Caution!
Risk of damage!
Always disconnect the power supply and
interrupt the CO2 supply before carrying
out maintenance work on the system. The plug-
in connector can then be disconnected.
Cleaning the cooling unit
For hygienic and health reasons, the cooling unit
must be cleaned once a year. Cleaning must be
performed before changing the filtercartridge,
in order to prevent contamination of the repla-
cement filter cartridge.
Reset error message E9, automatically approx.
20 minutes after cooling down to max. 32 ° C or
by interrupting the power supply approx. 30 se-
conds after cooling.
Let cool down the cooler for least 10 -15 min. If
EE flashes or the problem cannot be rectified,
interrupt the power supply to the ccooling unit.
Note down the serial number of the cooling unit
and consult the BWT customer service.
Replacement for the magnesium filter cartrid-
ge and the CO2 bottle can be ordered at www.
bwt-shop.ch.
Contact the BWT customer service to arrange a
service appointment.
BWT Customer Service
Tel.: +41 (0)800 88 99 88
E-Mail: aqadrink@bwt-aqua.ch

11. Technical data

Connection:
Voltage supply:
Max. power consump-
tion:
Type of protection:
Relative air humidity:
Refrigerant:
Safety shut-off of pump:
Operating pressure:
Max. CO2 inlet pressure:
Max. refrigerant pres-
sure:
Temperature classe:
Sanitary data:
Cooler/carbonator co-
oled water capacity:
Operating pressure:
Flow rate at 0.3 MPa flow
pressure:
Ambient temperature:
Temperature
- Cooler/carbonator
water inlet:
- Cooled water tempe-
rature:
Sound pressure level
L
A (freestanding):
p
Water connection
- Cooler/carbonator:
Electrical test data
Software class:
Contamination class:
Rated surge voltage:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and
rated current.
Technical data fitting:
Flow pressure:
Operating pressure:
Test pressure:
To comply with noise levels if static pressure exceeds 5
bar, a pressure reducing valve must be fitted.
Avoid major pressure differences between hot and cold
water supply.
Flow rate at 3 bar flow
pressure:
Temperature
Hot water inlet:
AQA drink Magnesium Mineralizer II
Wall socket with earth
wire, protected via a
10 A fuse
230 V AC / 50 Hz
240 W
IP21
max. 80%
0.030 kg - R600a
approx. 4:30 min
min. 0,2 MPa - max. 1
MPa
0,5 MPa
3,0 MPa
N
1,4 l
max. 0,55 MPa
ca. 2 l/min
4 - 35 ˚C
max. 24 ˚C
approx. 5 - 10 °C
50 4 ±dB
cold - blue
A
2
2500 V
0,2 - 0,9 MPa
max. 1 MPa
1,6 MPa
approx. 9 l/min
max. 70 °C
35