Télécharger Imprimer la page

Lincar 135GN Instructions D'usage Et Entretien page 23

Appareil à combustible solide : bois à brûler

Publicité

Les langues disponibles

Les langues disponibles

SECURITY DISTANCES
From NOT combustible object :
A > 400 mm B > 175 mm C > 200 mm D > 1500 mm
From combustible object and from principal wall in rein forced concrete :
A > 800 mm B >350 mm C > 400 mm D > 1500 mm
The minimal distance between the appliance and every flammable object around it is 1.5
meter.
To measure from external side of
the equipment
These are the measures in mm of different
equipments models.
Mod. 135GN - 135GN V
1.4 Connection
Before connection check technical data reported in the technical plate ( Chap. 4 ) and
control that it correspond to the ones required in the order.
All heating biomass equipment especially wood appliance has to evacuate the
combustion products in a flue built in conformity with normative in force.
The following instructions describes „ informations for a good installation „ and it refers
to a normative in force but it are not to be consider exhaustive for installations laws.
IT IT IT IT- - - - G G G G B B B B - - - - FR
FR- - - - ES
ES mod. 135GN-135GNV-145GN-145GNV
FR
FR
ES
ES
Mod. 145GN - 145GN V
23/76