6

Time memorization

Outputs LIGHT 1 and LIGHT 2 can be automatically deactivated. The time is between 6 secons up to 18 hours.
1
make sure the outputs are not activated
2
Put in ON the DIPB 3 for LIGHT 1 while put in ON the DIPB 4 for LIGHT 2
3
Activate the output LIGHT 1 or LIGHT 2
Press and release BUTTON P1
4
and while away the time in which the output should remain on.
5
Press and release BUTTON P1
If the procedure was successful,
6
the output will turn off automatically after the time stored.
It is important that the DIPB 3 or 4 remain in the ON position
7

Memorization of the twilight: LIGHT 1

The memorization of the twilight for LIGHT 1 is automatic. Follow the instructions for the installation:
obviously you have to connect a twilight in the terminal board no. 11-14
1
make sure the outputs are not activated
2
Put DIPB 1 in ON
3
Activate the output LIGHT 1
Press button P1 for the light value of output LIGHT 1:
4
DIPB 3 OFF for activate or DIPB 3 ON for deactivation
5
Twilight memorized
WARNING! during the memorization you need to put light in the
output LIGHT 1 where the sensor has to commute.