Electrical Requirements - Whirlpool YLEN2000LW0 Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
"
"
"
"
1. Recessed area
2. Side view - closet or confined area
3. Closet door with vents
Mobile Home-Additional Installation Requirements
This dryer is suitable for mobile home installations. The installation
must conform to the Canadian Manufactured Home Standard,
CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust system hardware which is available for
purchase from your dealer.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.

Electrical Requirements

WARNING
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance with the Canadian Electrical Code, C22.1-latest
edition and all local codes. A copy of the above codes
standard may be obtained from: Canadian Standards
Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3
CANADA.
"
"
"
"
"
3
A 4 wire, single phase, 115/230-volt, 60-Hz., AC-only
electrical supply is required on a separate 30-amp circuit,
fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual branch
circuit.
This dryer is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall
receptacle is within reach of dryer's final location.
4-wire receptacle 14-30R
If using a replacement power supply cord, it is recommended that
you use Power Supply Cord Replacement Part Number 9831317.
For further information, please reference the service numbers
located in your "Dryer User Instructions."
Replacement Power Supply Cord must be:
UL Listed or CSA International Certified
Marked for use with clothes dryers
Rated 115/230 volt minimum
30 amp
Type SRD or SRDT
4 conductors
At least 4 ft (1.22 m) long
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current. This
dryer is equipped with a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and ground-
ed in accordance with all local codes and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the dryer is proper-
ly grounded. Do not modify the plug provided with the dryer: if
it will not fit the outlet, have a proper outlet installed by a
qualified electrician.
3