Supplier's model identifi er
Model
Certifi cate CE
Nominal capacity
Real capacity
Nominal pressure
Nominal heat rating
Useful rating
Heating time for DHW t 45°C
Heat loss at 60° Celsius
Hot water fl ow rate
supply at 30K
supply at 45K
Erp
Declared Load profi le
Water heating effi ciency ηwh
Water Heating effi ciency class
Daily electricity consumption Q
Daily fuel consumption Q
Sound power level LWA L
Emissions of nitrogen oxides
Annual electricity consumption AEC
Annual fuel consumption AFC
Mixed water at 40°C V40
Set-point temperature "out of the box"
Thermostat temperature settings
Gas supply pressure
G20 Methane
G30 Butane LPG
G31 Propane LPG
gas consumption
G20 Methane
G30 Butane LPG
G31 Propane LPG
Combustion gas values
Draught
Flue gas fl ow rate
Flue gas temperature
For the list of equivalent models refer to Annex A, an integral part of this booklet.
The products without the label and its board for sets of heaters and solar devices, provided for in Regulation 812/2013,
are not intended for use in such sets.
All manuals and user guides at all-guides.com
TECHNICAL DATA
elec
fuel
WA
12 HP CA-E
I
120
I
110
bar
8
kW
10,2
kW
8,7
min.
42
W
270
I/h
249
l/h
166
L
%
66,1
B
kWh
0,040
kWh
19,298
dB
51
[mg/kWh]
129
kWh/annum
9
GJ/annum
14
l
156
°C
60
"E" (Eco)
mbar
20
mbar
28 ÷ 30
mbar
37
3
m
/h
1,079
g/h
803
g/h
792
mbar
0,015
g/sec
9,4
°C
130
ELECTRONIC
16 HP CA-E
20 HP CA-E
0694BN3853
150
200
160
185
8
8
14,2
14,2
12,1
12,5
41
49
310
340
347
358
231
239
L
XL
66,1
62,9
B
B
0,064
0,167
19,214
33,105
51
51
143
125
14
37
14
24
182
221
60
60
"E" (Eco)
"E" (Eco)
20
20
28 ÷ 30
28 ÷ 30
37
37
1,503
1,503
1118
1118
1103
1103
0,015
0,015
10,8
10,2
164
143
GB
65

Publicité

loading

Ce manuel est également adapté pour:

Electronic 16 hp ca-eElectronic 20 hp ca-e