4.0 appliance pre-installation
appliance pre-installation
EN
4.1
knockout plate removal
Before starting the DHM installation, remove the safety barrier. Refer to "safety barrier installation/removal" section
in the appliance installation manual.
WARNING
!
Both sets of knockouts MUST be removed when using DHM.
SINGLE-SIDED MODEL ILLUSTRATED
Front Frame
1.) Remove fasteners securing front frame (and rear
frame for see-thru). Do not discard fasteners.
SINGLE-SIDED MODEL ILLUSTRATED
3.) Remove the fasteners securing the cover plates recessed below the knockout plates. For ease of removal, lift
the panel from below in front of the fi rebox door. Discard cover plates.
IMPORTANT:
Fire Hazard Warning: This step is crucial for your appliance to work properly. If the
knockout plates AND the cover plates are not removed, the appliance will overheat, the
barrier will become excessively hot, and the high limit switch will constantly trip.
12
W415-3001 / A / 04.30.21
2.) Remove knockouts plates. Discard knockout plates.
Recommended: Use a fl athead screwdriver or a small pry
bar and use prying motion to remove the knockout. Use
a brace such as a piece of wood under the prying tool to avoid
distorting the top
Cover Plate
note:
Move appliance into place.
COVER PLATE