IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
SAFETY CONTROLS
The water heater is equipped with a combination
thermostat and high limit Energy-Cut-Off control (ECO)
that is located above the heating element in contact
with the tank surface. If for any reason the water
temperature becomes excessively high, the high limit
control (ECO) breaks the power circuit to the heating
element. Once the control opens, it must be reset
manually. Resetting of the high limit control should be
done by a qualified service technician.
CAUTION
The cause of the high temperature
condition must be investigated by a qualified
service technician and corrective action must be
taken before placing the water heater in service
again.
Remove the thermostat
cover.
READ AND SAVE THESE INSTRUCTIONS
Warning
Risk of fire or electrical shock. Failure to follow
the below instructions could result in death or
serious injury.
To reset the temperature-limiting control:
1. Turn off the power to the water heater.
2. Remove the thermostat cover.
3. Press the applicable RESET button.
4. Replace thermostat cover.
5. Ensure the water heater is operating properly
after resetting the ECO.
Press the manual reset button on the
appropriate thermostat.