Télécharger Imprimer la page

Jensen 141NG Manuel Du Propriétaire page 10

Publicité

Les langues disponibles

Les langues disponibles

WARNING
!
Before using this fireplace, make sure you have read, understand, and are following all information
provided in this manual. Failure to follow these instructions could cause property damage,
serious injury, or death.
Checking for Leaks
1. Make a leak check solution by mixing 1 part dishwashing soap with 3 parts water in a spray bottle.
2. Make sure the control knob on the fireplace is in the "OFF" position, then connect your
fireplace to the gas supply line and turn the gas on.
3. Spray the leak solution on the valve connections, paying particular attention to the areas
indicated by arrows in the diagrams below.
4. If bubbles appear, shut o the gas supply, disconnect the hose and inspect all connections
making sure threads are clear of debris. Reconnect the hose, turn the gas supply on and
retest. If you continue to see bubbles, turn the gas supply o , disconnect the hose, and call
Real Flame Customer Service at 1-800-654-1704 for assistance.
5. If no bubbles appear after 1 minute, wipe away excess leak solution and proceed to
"Lighting Instructions."
Pay close attention to the areas indicated by the arrows.
PRE-USE INSTRUCTIONS
10

Publicité

loading