Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
this submersible pump is designed to
supply water at the required pressure with
high efficiency and a long service life. to
maximize pump life, care must be taken in
its installation and usage.
Unpacking
after unpacking the submersible pump,
carefully inspect for any damage that
may have occurred during transit. Check
for loose, missing or damaged parts.
Safety Guidelines
this manual contains information
that is very important to know
and understand. this information
is provided for SaFety and to
PReVent eQUIPMent PRoBLeMS. to
help recognize this information, observe
the following symbols.
danger indicates an
imminently
hazardous situation which, if NoT
avoided, WIll result in death or serious
injury.
Warning indicates a
potentially
hazardous situation which, if NoT
avoided, Could result in death or serious
injury.
Caution indicates a
potentially
hazardous situation which, if NoT
avoided, MAY result in minor or moderate
injury.
Notice indicates
important
information, that if NoT followed, MAY
cause damage to equipment.
nOTe: Information that requires special
attention.
© 2011 Wayne/Scott Fetzer Company.
All manuals and user guides at all-guides.com
Deep Well
Submersible Pumps
General Safety
Information
CalIfOrnIa PrOPOSITIOn 65
including lead, known to the state of
California to cause birth defects and
other reproductive harm. Wash hands
after handling.
General SafeTy
1. Read the instruction manual
included with the product carefully.
Be thoroughly familiar with the
controls and the proper use of the
equipment.
2. Know the pump application,
limitations and potential hazards.
or explosive fluids such as gasoline,
fuel oil, kerosene, etc. do NoT use in
explosive atmospheres. Pump should
only be used with liquids compatible
with pump component materials.
Failure to follow this warning can result
in personal injury and/or property
damage.
pressure from the system before
attempting to install, service, relocate
or perform any maintenance. lock the
power disconnect in the open position.
Tag the power disconnect to prevent
unexpected application of power.
3. Personal Safety:
a. Wear safety glasses at all times
when working with pumps.
b. Keep work area clean, uncluttered
and properly lit.
c. Keep visitors at a safe distance from
work area.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.waynepumps.com
T50S10-2, T50S10-4, T51S10-4,
T75S10-2, T75S10-4, T100S10-2
4. Do not pump chemicals or corrosive
This product
5. When installing pump, prevent
contains chemicals,
6. always test the water from the well
7. Do not run the pump dry or
do NoT use to
licensed or certified electrician.
pump flammable
8. For maximum safety, the unit should
9. Make sure the line voltage and
10. Do not attempt repairs to the
disconnect power
and release all
11. avoid kinking electrical cord
connect the green wire (or green and
yellow wire) to a live terminal!
liquids. Pumping these liquids
shortens the life of the pumps seals
and moving parts and WIll void
warranty.
foreign matter from falling into
well, contaminating the water and
damaging internal mechanical
components.
for purity before use. Check with
local health department for test
procedure.
damage will occur and WIll void
warranty.
All wiring should
be performed by a
be connected to a grounded circuit
equipped with a ground fault circuit
interrupter (GFCI) device.
frequency of electrical current
supply agrees with the motor wiring.
electric motor. all repairs to the
motor must be completed at a
licensed or certified electrical motor
repair shop.
and protect electrical cord from
sharp objects, hot surfaces,
oil and chemicals. Replace or
repair damaged or worn cords
immediately.
Risk of electric
shock! NeveR
340601-001 5/11

Publicité

Table des Matières
loading

Sommaire des Matières pour Wayne T50S10-2

  • Page 9 Garder tous les visiteurs à distance sans danger du secteur de travail. MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. 9-fr © 2011 Wayne/Scott Fetzer Company. 340601-001 5/11...
  • Page 10: Système Électrique

    All manuals and user guides at all-guides.com Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces Généralités Sur la excessive menant à une usure BranCHeMenTS ÉleCTrIQUeS prématurée de la pompe, (2) l'eau Sécurité toutes les installations électriques (Suite) est corrosive, (3) du gaz ou de l'air doivent être conformes aux exigences entraîné...
  • Page 11 Câble monophasé à 2 ou 3 fils, 60 Hz (taille du fil en cuivre—du tableau au moteur) Système électrique Modèle Boîte de Tension fils pompe no. contrôle no. (Suite) t50S10-2 16965-002 la terre. Le système de mise à la t50S10-2 aucune terre doit être conforme à tous les codes de l'électricité locaux et t51S10-4 aucune nationaux en vigueur.
  • Page 12: Épissure De Fil

    All manuals and user guides at all-guides.com Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces Système électrique 5. Centrer la gaine sur le connecteur de bout, puis y appliquer de la (Suite) chaleur de manière uniforme avec Consulter les autorités compétentes un chalumeau (une allumette ou un EMBOUTIR OU SERTIR chargées d'appliquer les codes...
  • Page 13: Installation De Pompe

    All manuals and user guides at all-guides.com Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces Installation DÉMarraGe InITIal/nOUVeaUX ou à un démarreur magnétique (Suite) PUITS (voir Diagrammes de Câblage d'Installation). ne PaS encore Ne JAMAIs FAIRe Pour éviter de faire démarrer la pompe.
  • Page 14 All manuals and user guides at all-guides.com Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces Installation (Suite) 8. Une fois que l'eau est claire à ce stade, ouvrir entièrement la vanne BOÎTE DE CONTRÔLE à obturateur, puis faire marcher la SECTIONNEUR ÉLECTRIQUE (MODÈLES À...
  • Page 15 All manuals and user guides at all-guides.com Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces notes 15-fr...
  • Page 16: Mesures Correctives

    All manuals and user guides at all-guides.com Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces Tableau de dépannage Symptôme(s) Cause(s) Possible(s) Mesures Correctives Le moteur ne démarre pas, mais 1. aucune tension à la boîte de 1. Installer un fusible ou un fusible de type de surcharge les fusibles ne sont pas grillés contrôle ou au sectionneur approprié.
  • Page 17 All manuals and user guides at all-guides.com Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces Tableau de dépannage Symptôme(s) Cause(s) Possible(s) Mesures Correctives très peu d'eau ou rien n'est 1. Clapet de non-retour bloqué 1. Libérer la soupape si bloquée. Inverser la position de la pompé...
  • Page 18: Garantie Limitée

    Instructions D’utilisation et Manual de Pièces Garantie limitée Pendant un an à compter de la date d’achat, Wayne Water Systems (“Wayne”) va réparer ou remplacer, à sa discrétion, pour l’acheteur original toute pièce ou pièces de Pompes submersibles pour puits profond (“Produit”) déterminées défectueuses après examen par Wayne en termes de matériaux ou de fabrication.

Ce manuel est également adapté pour:

T50s10-4T51s10-4T75s10-2T75s10-4T100s10-2

Table des Matières