Installation Procedures; Electric Installation; Pneumatic Installation - Hofmann monty 1575 Notice D'utilisation

Table des Matières

Publicité

64
monty 1575
iii Installation procedures

Electric installation

THE INSTALLATION SHALL BE CARRIED OUT ONLY
BY QUALIFIED PERSONNEL AND WITHIN THE
SCOPE OF THE INSTRUCTIONS PROVIDED IN THIS
MANUAL.
Check on the plate of the machine that the electrical
specifications of the power source are the same as the
machine.
The machine uses
120 VAC, 60 Hz, 12 A
1 phase motor.
Electrical specifications are clearly marked on a label
at the end of the electric cable.
Before connecting the machine to the power source
check that the power supply has an efficient earthing
system.
Connect the electric cable of the machine with an
approved plug.
Note:
The outlet installation must be verified by
a licensed electrician before connecting
the tire changer.
Note:
The yellow/green wire in the cable is the
earth wire. Never connect the earth wire
to a live terminal.
Check that the power supply has an automatic circuit
breaker with a differential circuit rated at 30 mA.
The electric motor operates in a wide voltage range (plus
or minus 10%) and frequency range (60 Hz) and has a
class of insulation suitable for hot and moist climates.

Pneumatic installation

THE AIR INSTALLATION MUST BE PERFORMED
ONLY BY LICENSED PERSONNEL.
The machine requires an air pressure of 8 to 12 bar
(110-170 psi), as marked on the plate of the machine
and on a sticker attached to the cabinet next to the air
inlet.
Ensure that the line pressure is within the limits required
by the machine.
If the air pressure is lower than the minimum required
of 8 bar (110psi) the clamping power of the turntable
and the bead breaker power may be insufficient for
certain tIres.
Operator's Manual
USA - CANADA

Publicité

Table des Matières
loading

Table des Matières