Do not install the LED floodlight, if the LED floodlight is
replacing an existing light and there is no protective
earth cable available. First, draw a new mains cable.
Where the protective earth is not connected, a fault with
the mains voltage might result in the metal housing of
the LED floodlight becoming live. There is a risk of a
life-threatening electric shock!
When drilling in walls and ceilings, pay attention to ca-
bles, gas and water pipes.
Mounting/Installation
Unscrew the lock nut (5) from the cable
1.
gland (4) and guide the power cable
through the lock nut and the waterproof
grommet (6).
Connect the three
2.
wires of the power
cable with the lustre
terminals.
N = Blue
WARNING! Risk of electric shock! The floodlight may
only be operated when connected to ground.
Hint: If the floodlight glows faintly when OFF after con-
necting, switch the cables in the terminals L and N.
Re-tighten the lock nut (5).
3.
Operation
L = Brown/Black
= PE (Green/Yellow)
15