Symptom
The motor gets hot and
shuts off periodically
No power to controller
6.1
Service Technician Maintenance
This pump must be serviced by a professional service
technician qualified in pool/spa installation. The following
procedures must be followed exactly. Improper installation
and/or operation can create dangerous electrical hazards,
which can cause high voltages to run through the electrical
system. This can cause property damage, serious personal
injury, and/or death. Improper installation and/or operation
may void the warranty.
Before servicing the pump, switch off the circuit breakers
at the power source. Severe personal injury or death may
occur if the pump starts while your hand is inside the pump.
6.1.1
Blocked Impeller
1.
Turn off the pump. Switch off the circuit breaker to the pump motor.
2.
Remove the lid and basket.
3.
Look inside the pump and remove any debris.
4.
Replace the basket and lid.
5.
Switch on the circuit breaker to the pump motor.
6.
Turn on the pump, and see if the problem is solved.
7.
If the impeller is still blocked with debris and it is not possible to remove the debris using Steps 2 through 4, the
pump will need to be disassembled in order to access the inlet and outlet of the impeller.
Jandy
Variable-Speed Pumps, DV/DVS Models
®
Make sure that there is adequate room around the motor to circulate air and keep the
motor cool. Have a qualified electrician check for loose connections and check the
voltage at the motor while it is in operation. If the main voltage is outside of 10% of
the motor rating plate, the motor may be experiencing excessive loads. Contact your
local power surface provider.
This is exclusive to any contoller that is not an automation system. The motor has the ability
to power controllers through the RS-485 line. Have a certified electrician test the voltage on
the RS-485 line while there is power to the motor. There should be between 8 and 12 Volts
DC between pins 1 and 4. If the voltage is below or non existant, contact Zodiac Technical
Support at 800.822.7933.
Improper low voltage wiring. Check the wiring of the RS-485 connector. Wire colors
for pins 1-4 should be Red, Black, Yellow, Green.
CAUTION
WARNING
|
Installation & Operation Manual
Possible Cause/Solution

Publicité

loading

Ce manuel est également adapté pour:

Vsfhp165dvVsfhp185dvVsfhp130dvsVsfhp165dvsVsfhp185dvs