Technical data
Type
Power supply (V)
Consumption (W)
Max consumption (W)
ITE Classification
Operating temperature (°C)
Operating humidity (%)
Weight (Kg)
Fastening the module ��
Fasten the module to the supplied DIN rail, or to the
control panel by using the supplied brace and DIN rail.
The module can also be installed outdoors provided it is
encased with at least an IP54 protection rating.
Install the module away from any metal objects or
surfaces. In any case, do not fit it into metal casings.
Connections ��
⚠ Before any connection operations, IT IS OBLIGATORY
TO CUT OFF THE MAINS POWER SUPPLY.
All manuals and user guides at all-guides.com
UR042
9 - 30 (AC/DC)
2
3
B
- 40 ÷ + 85
10 ÷ 90
0.3
Should the device not be powered by a Came panel,
ensure that the power supply has current not greater
than 1A.
Connecting a single operator
Connect the module to the control board via terminals
(10-2) with a 2 x 0.5 PVC FROR cable (length max. 3 m)
ⓐ and to the GSM connector via
ⓑ ❶.
 With control boards with no GSM connector, connect
the module to terminals A-B-GND using a UTP CAT5 -
ⓒ ❷
AWG24-type cable
fit the RSE card; see the module compatibility table
Do not simultaneously connect to a the Micro Match
and the UTP CAT5 - AWG24.
Connecting to several operators
Connect the module to one of the control boards on
terminals (10-2) using a PVC FROR 2 x 0.5 (length max.
3 m) cable ⓐ and connect the RS-485 - in-out mode to
terminals A-B-GND using a UTP CAT5 - AWG24 cable
❸;
The maximum length of the UTP CAT5 cable is
1,000 m.
the cable Micro Match
and if required by the operator,
(*).