Note to Installer: Do not discard these installation instructions. Please give all installation
instructions, warranty registration and homeowner's manual to homeowner.
PRECAUTIONS AND GUIDELINES
The NuTone VSC4R door camera has been designed to work with NuTone models VSUC4RK or VSM4RK. Please read
and follow ALL installation instructions, guidelines and precautions. Any deviation from these instructions or miswiring
combinations will cause the unit to fail and all NuTone warranties will be void. Following are the installation instructions
for the VSC4R Camera. Please refer to the installation instructions and homeowners manual packed with the
VSUC4RK or VSM4RK when installation and operating these models.
WARNING: 120 Volt AC power to the VRM4R rough-in and VSM4SK monitor must remain off
until all system wiring and product mounting at the monitor and camera is complete.
Observe all local regulations and codes in your area.
All screw terminals at the camera, VSA4S optional handset (if installed) and monitor must be secure.
Observe all color codes of wires when connecting camera, VSA4S optional handset (if installed) and monitor.
The VSC4S is designed to be used with category 5, or category 6 cable (purchased separately). The use of cable
other than category 5, or category 6 cable will void all NuTone warranties and may result in faulty installa-
tion and improper operation.
The door camera must not be mounted in an area that would be subject to direct sunlight or a strong reflec-
tion from the sun.
Wiring Specifications
The VSC4R is designed to connect to the VSUC4RK, or VSM4RK video door answering system using category 5 or cat-
egory 6 cable.
• Maximum cable length: 250 ft
IMPORTANT: NuTone cannot be responsible for improper system operation that results from
interference generated by light dimmers, fluorescent lighting fixtures, and similar electrical
products. Such interference must be corrected at the source.
TO HELP REDUCE THIS INTERFERENCE, ALL WIRING CONNECTED TO THE CAMERA MUST BE
PLACED AT LEAST 12 INCHES FROM ANY A.C. POWER WIRING. AVOID RUNNING INTERCOM
WIRES PARALLEL TO A.C. POWER WIRING.
Connecting and Mounting the Camera
1. The VSC4R camera is designed to mount into the VRC4R rough-in. Refer to the instruction supplied with the
VRC4R rough-in for mounting and wiring information.
2. At the VRC4R rough-in location, strip approx. 2" of outer protective jacket from the category 5, or category 6 cable.
3. Separate and strip approx 1/2" of insulation from each of the eight wires in the cable. Twist the following cables
together:
• OR and OR/WH
• GR and GR/WH
• BL and BL/WH
• BR and BR/WH