nVent RAYCHEM T2Red Manuel D'installation page 41

Système de chauffage
Masquer les pouces Voir aussi pour T2Red:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 44
used for glueing tiles in color sensitive natural stone. In order to be able
to guarantee proper adhesion to the Reflecta plates, nVent cannot accept
responsability for installations carried out with other adhesives.
If ceramic tiles are to be glued directly onto the Reflecta plate, the plate
must be glued using the Reflecta A-Fix glue or screwed. Before applying
the Reflecta P-FIX primer, any grease should be removed from the
Reflecta with methylated spirits. The grouting between tiles should be
completed with a flexible filler 24 hours after the installation of tiles. The
heat may be turned on 24 hours after the grouting is completed. Always
follow the suppliers instructions for glueing or grouting the tiles.
Technical data of Reflecta plate
Storage temperature
Min. installation temperature
Max. installation temperature
Never expose Reflecta plates
to direct sunlight.
Minimum operating temperature
Maximum circuit length of
T2Red is depending on the
start-up temperature:
Dimensions
End plates
Reflecta plates
Material
Fixing material
Max. allowed height difference
FLOOR CONSTRUCTIONS
Fig C: T2Red & Reflecta with tiles or natural stone
1. Ceramic tiles or natural stone
2. Flexible tile adhesive
3. Reflecta P-Fix
4. T2Red
5. Reflecta plates
6. A-Fix
7. Suitable primer for the subfloor
8. Subfloor (Concrete, wooden plates, wooden floor, etc)
–20°C to +50°C
+5°C
+30°C
+5°C
100m at 20°C
85m at 15°C
75m at 10°C
60m at 5°C
400 mm x 100 mm x 12,5 mm
720 mm x 400 mm x 13,0 mm
EPS + aluminium plate
Reflecta adhesive or screwed
max. 2 mm per m