To Stop The Product; To Start The Product - Husqvarna K 7000 Manuel D'utilisation

Masquer les pouces Voir aussi pour K 7000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. Push the knob to stop the flow of water.
The water goes through the return hose.

To start the product

1. Hold the rear handle with your right hand.
2. Push the power trigger lockout and hold in the power
trigger.
Lamp indicators in the product
Indication
1 green lamp flashes. The product is connected to a power pack and is pre-
2 green lamps flash.
3 green lamps flash.
3 green and 1 yellow
lamps flash.
3 green, 1 yellow and
1 red lamps flash.
1448 - 003 - 13.02.2020
Cause
pared for operation.
The power output is less than 70% of the maximum
available output in operation.
The power output is 70-90 % of the maximum available
output in operation.
The cutting speed is at its best performance.
The power output is 90 % of the maximum available out-
put in operation.
The power output drops.
The product is too hot.
3. Let the product operate with no load for 30 seconds.

To stop the product

WARNING: The cutting blade continues to
rotate for a while after the motor stops. Make
sure that the cutting blade can rotate freely
until it fully stops. If it is necessary to stop
the cutting blade quickly, let the cutting
blade lightly touch a hard surface. Risk of
serious injury.
There are 2 procedures to stop the motor.
Release the power trigger to stop the motor.
Push the machine stop button on the power pack.
Refer to the operator's manual for the power pack.
Step
N/A
N/A
N/A
Decrease the load.
Decrease the load or increase
the water flow or airflow to de-
crease the temperature.