4100 Insert ACC
REMARQUE : Les dégagements ne peuvent être diminués que si cela est autorisé par les autorités
compétentes.
A. Exemple d'étiquette de numéro de série / de sécurité
EMPLACEMENT : EN-DESSOUS DU COLLECTEUR DE CENDRES SUR LA PLAQUE COULISSANTE
Numéro du test
du laboratoire et 
du rapport
2
et Bienvenue dans la famille Quadra-Fire!
INSTALLATION MANUAL
LISTED ROOM HEATER,
SOLID FUEL TYPE.
"For Use with Solid Wood Fuel Only."
Also for use in Mobile Home.
PREVENT HOUSE FIRES
Install and use only in accordance with manufacturer's installation, venting and operating
instructions.
CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA
Refer to manufacturer's instructions and local codes for precautions required for passing
chimney through a combustible wall or ceiling.
WARNING - For Mobile Homes: Do not install in a sleeping room. An outside
combustion air inlet must be provided and unrestricted while unit is in use. The structural
integrity of the mobile home floor, ceiling and walls must be maintained. The insert must
be properly grounded to the frame of the mobile home. A complete relining of the chimney
system with a 6 inch (152mm) diameter listed stainless liner is required. Must be
equipped with a spark arrestor cap. Outside Air comes standard on the insert and must be
installed before operating insert.
When used as a masonry insert stove, install only in a masonry fireplace built to national
and/or local codes. Do not remove brick or mortar to accommodate insert. Installation
requires a 5 foot minimum length of a starter pipe into existing chimney with airtight face
seal.
Install only on a non-combustible hearth. Approved for installation and use in factory built
zero-clearance fireplaces conforming to minimum fire chamber specifications.
Components required for installation: positive or direct flue connection assembly or listed
vent liner.
In Canada a full length
6 inch (152mm)
S635 flue liner is required as per ULC S628-93.
WARNING - Inspect and clean chimney frequently. Under certain conditions of use,
creosote buildup may occur rapidly.
Do not connect this unit to a chimney serving another appliance.
DANGER: Risk of electrical shock. Disconnect power supply before servicing. Route
power cord away from unit. Do not route cord under or in front of appliance.
Electrical Rating: 115 VAC
1.4 AMPS 60 Hz
Do not use grate or elevate fire.
Build wood fire directly on hearth
(firebrick). Do not overfire. If heater
or chimney connector glows, you are
overfiring. Operate only with doors
closed. Open only to add fuel to the
fire. Replace glass only with 5mm
ceramic available from your dealer.
This wood heater needs periodic
inspection and repair for proper
operation. Consult the owner's
manual for further information. It
is against federal regulations to
operate this wood heater in a
manner inconsistent with the
operating instructions in the
owners's manual.
Factory-Built
Floor
Protection under Hearth Extension
Thermal & Ember Protection
A
Floor height 0 to 1-3/4 inches below Insert
B
Base:
1/2 inch R=2.38
C
D
Ember Protection Only
E
Greater than 1-3/4 inches below Insert
F
Base:
CAUTION:
TOUCH, KEEP CHILDREN, CLOTHING AND
FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. SEE NAMEPLATE AND INSTRUC-
TIONS.
Model:
4100i ACC
4001508
WOOD INSERT
CONFORMS TO UL STD 1482
CERTIFIED TO ULC STD S628
Mfg by:
352 Mountain House Road, Halifax, PA 17032
- Certified to comply with 2015 particulate emission standards
U.S. ENVIRONMENTAL PROTECTION AGENCY
g/hr EPA method 28 and 5G.
Not approved for sale after May 15, 2020.
JAN FEB MAR APR MAY JUN
DO NOT REMOVE THIS LABEL
2019 2020 2021
FC7045-909J
OWNERS MANUAL
Maximum Mantel Depth - 12 inch (305mm)
Mantel
B
Fascia or Trim
C
Insert
A
D
Fuel Door
E
F
Hearth Extension
Minimum Clearances To Combustible Material
Masonry, Heat Circulating &
Factory-Built
Refer to Clearances on other label for Canada
USA ONLY
Sidewall to Fuel Loading Door
22 in.
Mantel to Top of unit
23 in.
Top Trim to Top of unit
21 in.
Side Trim to Fuel Loading Door
11 in.
Hearth Extension from Glass
16 in.
Hearth Extenson from Fuel Loading Door
8 in.
HOT WHILE IN OPER-
ATION DO NOT
Serial No. / N° de série
R
HF
BARCODE LABEL
www.quadrafire.com
at 4.3
JUL AUG SEP OCT NOV DEC
Made in U.S.A. of US and
imported parts.
7045-179F
Numéro de série
Modèle
Date de fabrication
10 Janvier, 2020