MounTing oPTionS (1) wiTh cLAMPing LeVeRS And (2)
wiTh cLAMPing ScRewS
MAinTenAnce And inSPecTion oF The MAgneTic cLAMP
Regular maintenance and inspections are necessary to ensure the safe use of the switchable
magnetic clamp. Furthermore, country-specific standards and regulations must be observed
depending on application.
The maintenance intervals are classified according to the recommended schedule.
before every use...
• visually inspect the magnet for damage
• clean the surface of the workpiece and the underside of the magnet
• free the underside of the magnet of rust, chips or unevenness
weekly...
• inspect the magnetic clamp for deformation, cracks or other defects
• make sure the activation lever is working properly and latches correctly into place
• inspect the bottom of the magnet for scratches, pressure points or cracks and have the magnet
repaired by the manufacturer if necessary
Monthly...
• check the markings and labelling on the magnet for legibility and damage and replace them if necessary
Annually...
• have the load-bearing capacity of the magnet checked by the supplier or an authorized workshop,
should the application so require
unauthorized repairs or modification to the magnetic clamp are not permitted.
!
if you have any questions, contact the manufacturer.