STORAGE
If the battery is not used for a longer period, it needs to be recharged every 4 months for
12 hours (if the storage temperature is lower than 25° C). If the storage temperature is
higher than 25° C, the battery needs to be recharged every 2 months for at least 12 hours.
CLEANING
Clean this device with soft, dry cloth. Do not use any chemical agents to clean this
product. Before cleaning, make sure the device is switched off and disconnected from
the power supply.
SPECIFICATIONS
Overvoltage protection point
AC Input voltage range
AC Input frequency
AC Output frequency
AC Output waveform
AC output efficiency
Environment temperature
Environment humidity
EN
English
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems) This marking
shown on the product or its literature, indicates that it should not be disposed with other household wastes at the
end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste
disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable
reuse of material resources. Household users should contact either the retailer where they purchased this
product, or their local government office, for details of where and how they can take this item for environmentally
safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase
contract. This product should not be mixed with other commercial wastes for disposal.
Made in China for Lechpol Electronics Leszek Sp.k., ul. Garwolińska 1, 08-400 Miętne.
20
Model
Nominal power
Battery voltage
AC Output voltage
Charge current
Conversion time
Protections
Owner's manual
PROsinus-1600
190 - 260 VAC
45~60 Hz
AC: 230 VAC ±5% / Inv. 230 VAC ±3%
50/60 Hz ±0.5 Hz
Pure sine wave
≥ 85% (DC to AC)
Max. 20 A
Overload, short circuit, overvoltage, undervoltage
1600 W
12 VDC
15 VDC
≤ 4 ms
0-40° C
10-90%

Publicité

loading

Ce manuel est également adapté pour:

Urz3431 prosinus-1600Prosinus-1600Urz3411Urz3431