RH006
Standard
Hood Heights
Duct Cover
minimum ducted (A) 27-1/2"
minimum recirculating (B) 32"
maximum (C) 42-1/2"
Ceiling Heights
minimum ducted (D) 87-1/2"
minimum recirculating (E) 92"
maximum (F) 104-1/2"
RH008
Standard
Hood Heights
Duct Cover
minimum ducted (A) 26"
minimum recirculating (B) 31"
maximum (C) 49"
Ceiling Heights
minimum ducted (D) 86"
minimum recirculating (E) 91"
maximum (F) 119"
RH009
Standard
Hood Heights
Duct Cover
minimum ducted (A) 27"
minimum recirculating (B) 31"
maximum (C) 48"
Ceiling Heights
minimum ducted (D) 87"
minimum recirculating (E) 91"
maximum (F) 118"
DUCTING
A minimum of 6" round duct must be used to
maintain maximum air flow efficiency.
Always use rigid type metal ducts only. Flexible
A
n .
ducts could restrict air flow by up to 50%.
m i
B
n .
m i
x . C
Use calculation worksheet to compute total duct
m a
work (Page 5).
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
i n .
a x .
" m
increase duct size from 6" to 7" or 8".
2 4
" m
3 4
If turns or transitions are required: Install as far
away from duct opening and as far apart between
the two transitions as possible.
Minimum mount height between range top to hood
bottom should be no less than 24".
"
Maximum mount height should be no higher than
34".
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and fire hazard; while hoods
Extension
mounted too high will be hard to reach and will
Duct
Cover
46-1/2"
loose performance and efficiency.
50-1/2"
80"
If available, also refer to range manufacturer's
height clearance requirements and recommended
106-1/2"
hood mounting height above range. Always check
110-1/2"
your local codes for any differences.
150"
Duct cover extension kit available for ceiling
Extension
Duct
Cover
heights up to 12 feet. Turn to page 20 for part
41"
number and ordering information.
45-1/2"
78-1/2"
DAMAGE-SHIPMENT / INSTALLATION:
• Please fully inspect unit for damage before
101"
installation.
105-1/2"
• If the unit is damaged in shipment, return the
148-1/2"
unit to the store in which it was bought for
Extension
repair or replacement.
Duct
Cover
• If the unit is damaged by the customer, repair
43"
or replacement is the responsibility of the
47"
customer.
81"
• If the unit is damaged by the installer (if other
than the customer), repair of replacement must
103"
be made by arrangement between customer
107"
151"