CFM SELECT
Some local codes limit the maximum amount of CFM a range hood can move. CFM Select allows you to control
the maximum blower CFM of the range hood without the need for expensive make up air kits. CFM Select enables
the installer to easily set the maximum blower speed to one of two most commonly specified CFM levels; 390 or
290 CFM. The usage of CFM Select may not be necessary for your installation. Please check your local codes for
CFM restrictions.
By default the maximum blower CFM is set to 600.
!
CAUTION:
Hood must be disconnected from main power prior to performing the
conversion instructions listed below. Failure to do so could result in
personal injury or damage to the product.
To enable CFM Select
1. Before hood installation, gain access to PC board by following the steps shown in FIG. C.
2. Change plastic jumper positioning as shown in FIG. D to set the desired maximum blower CFM.
3. Re-install PC board & continue with hood installation.
4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below
the wiring diagram or in another clearly visible location.
NOTE: After re-positioning the jumper and powering on the hood, the CFM cannot be changed again.
To verify if your installer enabled CFM Select
With hood off, press and hold the power button for five seconds. If 3 LEDs illuminate = defualt max. CFM, if 2 LEDs
illuminate = max. 390 CFM, and if 1 LEDs illuminate = max. 290 CFM.
When CFM Select is enabled, the number of blower speeds will be reduced. 390 CFM = max. 2 speeds and 290
CFM = max. 1 speeds.
There should also be a foil label located inside the hood body near the wiring diagram that indicates the blower
CFM.
- PC Board is located behind light panel.
- Remove baffle filters and light panel.
- Remove 2 screws attaching control board
assembly.
FIG. C
7
LAMP
5
3
MOTOR
7
8
1
5
6
3
4
1
2
J u m p e r
Max. Blower CFM
390
PC Board
FIG. D
17
Jumper Pins
Plastic
7
8
Jumper
5
6
3
4
1
2
J u m p e r
5 - 6 or 7-8
DEFAULT POSITION
Default Max. Blower CFM
8
7
8
6
5
6
4
3
4
2
1
2
3 - 4
J u m p e r
1 - 2
Max. Blower CFM
290