WET & DRY VACUUM CLEANER F13F1
OPERATIG INSTRUCTIONS
These opereting instruction provide you with all information necessary
for correct , safe and prescribed usage and maintenance of the series
DRY and WET & DRY VACUUM CLEANER (ALL THE
MODELS). They must be kept where they are accessible to the user at
all times.
PRESCRIBED USAGE
This machine is designed for the professional cleaning according to these
operating instructions.
Any other usage, in particular, for the removal of types of dust whch may
be dangerous to health, is prohibited.
GENERAL SAFETY INSTRUCTIONS
This machine is designed and constructed according to che present state
of the art and recognised technical safety standards. It is fitted with
protective devices, following safety European standard rules. Dangers
can occur in spite of this, in particular in the case of maloperation or non-
compliance with the specifications and information in the operating
instructions.
All our equipements are coverde by international assurances against
risks.
1) Sources of danger
- Electrical voltage / Electric current
- Warning: Danger
Contact with voltage or current carrying parts carries the risk of electric
shock which can result in serious injury or even death. Never touch
damaged cables. Always switch off and disconnect the power supply
before carrying out any work on the machine. Replace faulty cables
immediately.
2) Improper usage
Any usage of the machine for a purpose not covered under the
"Prescribed usage" or contractually agreed purpose is not permissible.
The use of the machine in an unserviceable condiction or not in
compliance with the following prescription is prohibited:
- Protective devices must not be removed or bypassed.
- Conversions and modification to the machine are not permitted.
- Defective supply cables are only to be replaced by original
FIORENTINI cables.
- Coupling elements between mains supply or detachable extension
cables must be at least splashproof.
- The machine is to be fitted with a type H circuit breaker for rated
current of 10 A for the vacuum with 1 or 2 motors and 15 A for 3
motors.
3) Organisational points
It is the responsibility of the operator to ensure that:
- The machine is used only by personnel who have been instructed in its
handling and authorised to use it.
- The recognised occupational safety regulations are observed.
- Any further national or internal company regulations are abserved.
- All users are acquainted with the safety regulations and trained in the
use of the specific machine.
- All users have read and understood the operatin instructions.
- Responsabilities for the operation, maintenance and repair of the
machine are clearly assingned and abserved.
- Faults and damage are immediately notified to the Service Agent of
FIORENTINI.
4) In the case of an emergency
- Pull out the mains connector plug.
- Immediately apply recognised first-aid measures.
After incidents, do not resume operation with the machine until it has
been inspected by FIORENTINI autorized technical.
5) Opetating for the first time
Delivery, instruction on safety rules, handling and maintenance as well as
operation for the first time must be carried following the specification of
this instruction book. The operator is responsible for instructing the users.
FUTHER SAFETY INSTRUCTIONS CONCERNING OPERATING
AND MAINTENANCE ARE DETAILED IN THE RELEVANT
SECTIONS AND MUST BE COMPLIED WITH!
ASPIRATEUR EAU/POUSSIERE F13F1
IMPORTANT NOTES
BEFORE STARTING TO USE THE CLEANER PLEASE OBSERVE
THE FOLLOWING POINTS:
- If you should discover any damage when unpacking the cleaner please
inform your sale agency.
- Certain parts are packed in the tank to protect them from damage. These
should be removed before the cleaner is put into use.
- The supply voltage must be the same as that shown on the nameplate.
ELECTRICAL CONNECTION AND SUPPLY
WARNING: - This appliance must be earthed!
- Check that the supply voltage details given on the rating plate are in
accordance with your electricity supply.
CAUTION!
- The cleaner should never be used for picking up hot ashes, explosive
fluids or undiluted acids or solvents. These include petrol, paint thinner
and heating oil, all of which can generate explosive mixtures or vapours
when swirled together with the suction air. Acetone, undiluited under
acids and solvents would attack the materials from which the machine is
made.
WARNING NOTE
- For cleaning or servicing the cleaner or when replacing parts, the motor
should be switched off and the connecting plug be withdrawn from the
socket.
- Care should be taken to ensure that the connecting calble is not damage
by being driven over, crusced, strained, etc.
- The connecting cable should be regularly checked for any signs of
damage or ageing.
- The machine must not be used if the conneting cable is not in a proper
condition.
- For suction of dry dust, check that the filter are in the vaccum cleaner,
also for draw up liquids care to take out the filter from the vaccum
cleaner.
- Do not use foaming chemical.
- Do not clean the vaccum with a water pipe to avoid that water get
trought the vaccum head.
UTILIZATION
1) First operation before use
- Introduce the flex hoses in the hole of the machine until the click insert.
Look that the seal ring is on right position.
- Put the accessory that you need on the hoses.
2) Transport
- To avoid damage during the transport by car or by truck, the vaccum
cleaner must be put inside his original package.
MAINTENANCE AND CLEANING
ATTENTION
Take out the plug before any maintenance operation on the head of the
machine.
NORMAL OPERATION OF MAINTENANCE:
- Clean the vaccum cleaner inside and outside.
- Clean the rubber which is in the cover of the head.
- Check the hoses and the electric cable.
IF LOOSE POWER
- Check the filter.
IMPORTANT: IF YOU CLEAN THE FILTER MICROWEB WITH
WATER, WAIT THAT IT IS DRY BEFORE TO INSERT IN THE
VACCUM AGAIN.
TROUBLE SHOOTIN
FAULT
Motor (suction
No electrical power
turbine) does not start
Suction slowly
Filter,nozze,suction hose or
decreases
extensios tube blocked
Suction suddenly
The paper filtre bag or the
decreases
tank is full
Dust ascapes when
Filter incorrectly or
cleaning
defective
CAUSE
REMEDY
Check fuse,cable,plug
and socket
Check and clean
Switch off the cleaner
and empty
Check filter sealing.
Replace filter