Troubleshooting
Any malfunctions that cannot be removed by means of the measures
described in this chapter may only be repaired by the manufacturer.
Problem
Green LED is not on
Red LED is on
Yellow LED flashes
Water in condensate
trap
Filter polluted
Other malfunctions
39
Troubleshooting
Eurovac NV
Possible reason
No power supply
Leak detected
Test/measurement
valve in position
"Test/Vent"
Condensate trap or liq-
uid barrier open
Annual maintenance
required
-
-
-
Repair
Provide power supply
Check the hoses and
hose connections
Notify the installation
company
Set the test valve and
the measurement valve
to position "Normal
Operation"
Close the condensate
trap or the liquid barrier
Perform annual mainte-
nance (see
chapter "Maintenance")
Drain the condensate
trap.
Replace the filter
Contact the AFRISO
service hotline