Directions For Use; Connection; Disconnection; Important - Nederman Exhaust Hose Reel 865 Manuel D'instruction

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
4.10

Directions for use

4.10.1

Connection

Pull the hose out to desired position and make sure that it is in engaged
position. Connect the nozzle to the vehicle exhaust pipe (See Figure 8).
WARNING!
Risk of severe personal injury
• Check that there is enough suction in the exhaust hose before it is connected
to the vehicle's exhaust pipe. If not, check the fan's rotation direction and/or
damper function. If necessary check installation of fan start switch.
• An exhaust gas detector is recommended.
4.10.2

Disconnection

Disconnect the nozzle from the vehicle exhaust pipe. Draw the hose out a little
to disengage the ratchet. The hose now recoils to the drum and it should be
held by hand until it has moved to its end position. Make sure that the hose
only forms one layer on the drum (See Figure 9).
4.11

IMPORTANT!

See Figure 10. If the hose is pulled out too far, the ratchet could unfortunately
become permanently locked. It may be released by the following procedure.
1.
Take a steady grip in the drum end plate and turn a little in the outdraw
direction until the ratchet is disconnected.
2.
Holding the end plate and hose at the same time, then slowly release until
the hose has been recoiled.
3.
Fit the ratchet in the other mounting position.
5

Maintenance

5.1

Service instruction

Check the following points at least once a year. Take actions when necessary.
Check that the reel is secured in the ceiling or on the wall.
Check the duct connections for leakage.
Check the hose for damage.
Check the coiling function of the hose. Adjust the spring power when
necessary. See page 14.
Check the hose connection in the connection piece inside the drum.
Check operation of the damper. The damper should open automatically
when the hose is pulled out.
Check that there is enough suction in the exhaust hose. If not, check the
fan's rotation direction and/or damper function. Check the hose for holes.
Exhaust Hose Reel Serial 865
EN
144233(02)
15

Publicité

Table des Matières
loading

Table des Matières