• Clavier LED;
Zone 1 - [23] [01] → [1-2-3-4-5-6-7] → [√ OK]
Zone 2 - [23] [02] → [1-2-3-4-5-6-7] → [√ OK]
Zone 3 - [23] [03] → [1-2-3-4-5-6-7] → [√ OK]
Zone 4 - [23] [04] → [1-2-3-4-5-6-7] → [√ OK]
Zone 5 - [23] [05] → [1-2-3-4-5-6-7] → [√ OK]
Zone 6 - [23] [06] → [1-2-3-4-5-6-7] → [√ OK]
Zone 7 - [23] [07] → [1-2-3-4-5-6-7] → [√ OK]
Zone 8 - [23] [08] → [1-2-3-4-5-6-7] → [√ OK]
• Clavier LCD;
[Zone Settings √ OK]→[Extra Settings √ OK]→[1- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[2- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[3- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[4- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[5- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[6- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[7- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[8- Zone Options 1-2-3-4-5-6-7]→[√ OK]
PS: (1) Les options 2 et 3 ne peuvent pas être activées en même temps dans une zone.
(2) La fonction ''Cross Zone'' s'applique uniquement aux zones sélectionnées comme porte,
fenêtre, interne et externe. Il n'est pas recommandé d'utiliser la fonction de zone croisée dans
les zones temporisées et suiveuses.
7.5.5 Temps de réponse ''Response Time''
La centrale ne détecte pas le mouvement de contact comme une alarme pendant moins de temps que
prévu. Cette valeur peut être réglée entre 2 et 255. Chaque nombre définit une augmentation de 30
millisecondes. Par exemple, si cette valeur est entrée 15, le temps de réponse sera de 15x30ms = 450
millisecondes.
• Clavier LED;
Zone 1 - [24] [01] → [XX] → [√ OK]
Zone 2 - [24] [02] → [XX] → [√ OK]
Zone 3 - [24] [03] → [XX] → [√ OK]
Zone 4 - [24] [04] → [XX] → [√ OK]
Zone 5 - [24] [05] → [XX] → [√ OK]
Zone 6 - [24] [06] → [XX] → [√ OK]
Zone 7 - [24] [07] → [XX] → [√ OK]
Zone 8 - [24] [08] → [XX] → [√ OK]
• Clavier LCD;
[Zone Settings √ OK]→[Response Time √ OK]→[1- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[2- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[3- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[4- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[5- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[6- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[7- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[8- Zone Delay XX]→[√ OK]