Télécharger Imprimer la page

IRSAP 1028M1219 Mode D'emploi page 7

Sèche-serviettes avec réglage de la température interne

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
Towel warmer with internal
temperature adjustment
IRSAP SPA
45031 Arquà Polesine (RO) Italy
Tel. +39 0425 466611 - Fax +39 0425 466662
Website: http://www.irsap.com
E-mail: info@irsap.it
----------------------------------------------------------
IR GROUP SARL
19,Chemin de la Plaine 69390 Vourles (France)
Tel. +33 04 28 00 01 67 - Fax +33 04 72 31 86 40
Web: http://www.irsap.com;
E-mail: irsaprhoss@irgroup.fr
----------------------------------------------------------
IRSAP IBERICA S.L.
Oficina y Almacèn: P.I.CAMI RAL
Leonardo da Vinci,4 08850 Gavà (Barcelona)
Tel. 93 633 47 00 - Fax 93 633 47 04
E-mail: informacion@irsap.com
www.irsap.com
----------------------------------------------------------
IRROM Industrie S.R.L.
Str. Pricipalà 1/A, Sat Fundàtara, Iclod 407336,
jud. Cluj, Romània
Tel: +40 (0)264 263400 - Fax: +40 (0)264 263404
Web: www.irsap.ro
The towel warmer is an electrical appliance endowed with the following features:
• Voltage-feed 230V 50Hz, 1ph
• Insulation Class I
• Protection degree IP44
• Length electrical cable 1200 mm
• Electronic ambient thermostat.
The association between electrical heater and towel warmer allows a radiator surface temperature no higher than about 70°C
The towel warmer is filled in the factory with a measured quantity of a special liquid, to optimize the heat transmission.
Because of this, any repairs which require the opening of the towel warmer, must be executed from the manufacturer.
This applies equally in the unlikely event of the special liquid leaking out of the towel-rail.
The thermostat can work exclusively when paired with a specially prepared electric heating element, equipped with safety devices to limit excess
temperature and make the system safe in the event of abnormal factors (see Warnings).
The towel warmer must be installed by qualified staff.
Always fix the towel warmer to the wall as per the assembly instructions enclosed.
The installation must be carried out by a specialized firm in compliance with the standards in force.
When installing the towel warmer the BS EN 60364-7-701 according to the edition in force must be complied
For the supply of the towel warmer, an omnipolar switch with at least 3 mm of distance between contacts, must be employed.
When installing in bathrooms or in shower-rooms, the appliance should be installed in such a way to avoid the switch and other controls to be reached
by people using the bathroom or the shower. (see Fig. B)
The towel warmer must not be installed immediately beneath a fixed current outlet.
Take utmost care while installing the towel warmer to avoid damaging the electronic thermostat and the connecting cable.
In order to avoid every risk to the smallest children, we recommend installing the device in such way that the lowest heating pipe is at least 600 mm
above the ground.
The towel warmer must be used only for the purpose described in the manual. In particular, children must not play with the appliance.
Do not apply on the towel warmer radiator accessories other than those prescribed or recommended by the manufacturer.
Connect the towel warmer to the mains power supply only after it has been fixed to the wall.
Children under 3 must be kept at a distance unless under continuous surveillance.
Children between 3 and 14 years of age and persons with reduced physical, sensory or mental capacities, or who lack experience or the necessary
knowledge can use the towel warmer on condition that it has been positioned or installed in the normal position contemplated and they have been
instructed and trained in its safe use and are aware of the potential risks.
Children under the age of 14 must not connect the power plug, nor adjust or clean the appliance.
Children and persons with reduced physical, sensory or mental capacities, or who lack experience or the necessary knowledge must not perform
cleaning or routine maintenance of the towel warmer towel warmer.
It is absolutely prohibited:
To power the heating element control before having checked the correct installation of the thermostat on the towel warmer towel warmer.
-
To cut the power supply cable to disconnect the appliance
-
To damage the power supply cable. If the power cable is damaged the complete electric heating element must be repaired or replaced by the
-
manufacturer or by their technical assistance service, or by a qualified person authorised by the manufacturer, so as to prevent any risk.
WARNING:
DURING OPERATION, THE TOWEL WARMER PRESENTS HOT SURFACES, SOME PARTS CAN GET VERY HOT, AND CAUSE
BURNS UNLESS PARTICULAR CARE IS TAKEN. Particular attention should be paid to the presence of children and vulnerable people
During operation it is normal for the last two pipes at the bottom and the first one at the top to remain lukewarm.
-
Only fabrics washed with water can be dried on the towel warmer.
-
Do not use corrosive or abrasive products or solvents to clean towel warmer or the plastic parts that contain the electrical parts.
-
Cod. 1028M0219