Zephyr Essentials Modena ZMD-M90AS Guide D'utilisation, D'entretien Et D'installation page 8

Publicité

Les langues disponibles

Les langues disponibles

D
n .
m i
E
n .
m i
x . F
m a
Standard
Hood Heights
Duct Cover
minimum ducted (A) 28"
minimum recirculating (B) 32"
maximum (C) 50"
Ceiling Heights
minimum ducted (D) 90" (7' 6")
minimum recirculating (E)
94" (7'10")
maximum (F)
120" (10')
DUCTING
A minimum of 8" round duct is recommended to
Always use rigid type metal ducts only. Flexible
Use calculation worksheet to compute total duct
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 8" to 10".
If turns or transitions are required: Install as far
away from duct opening and as far apart between
the two transitions as possible.
A
n .
Minimum mount height between range top to hood
m i
B
n .
m i
bottom should be no less than 26".
x . C
m a
Maximum mount height should be no higher than
34".
i n .
" m
a x .
2 6
" m
3 4
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
mounted too high will be hard to reach and will
"
If available, also refer to range manufacturer's
3 6
height clearance requirements and recommended
hood mounting height above range. Always check
your local codes for any differences.
Duct cover extension kit available for ceiling heights
Extension
up to 12 feet. Turn to page 21 for part number and
Duct
Cover
ordering information.
41
"
1/2
45
"
1/2
80"
DAMAGE-SHIPMENT / INSTALLATION:
103
" (8' 7
")
1/2
1/2
107
" (8'11
")
1/2
1/2
150" (12' 6")
installation.
unit to the store in which it was bought for
repair or replacement.
or replacement is the responsibility of the
customer.
be made by arrangement between customer
and installer.
6
www.zephyronline.com