5.5.3 Exemplary settings
Example 1 is the factory setting (since factory settings are entered by computer, all DIP switches of a
new product are set to 'off', except for DS-2).
DS-1 Panel option
DS-2 Panel option
DS-3 Ch. voltage
DS-4 Ch. voltage
DS-5 Frequency
DS-6 Search mode
DS-7 AC-in Limit
DS-8 Store setting
Example 1: (factory setting)
1
No panel or remote
switch connected
2
No panel or remote
switch connected
3, 4
GEL 14.4 V
5
Frequency: 50 Hz
6
Search mode off
7
AC-in Limit 12 Amp
8 Store setting: off→ on→ off
Store the settings (DS3-DS7) by changing switch ds-8 from off to on, and then back to off.
The LEDs 'charger' and 'alarm' will flash to indicate acceptance of the settings.
6. MAINTENANCE
The EasyPlus does not require specific maintenance. It will suffice to check all connections once a year.
Avoid moisture and oil/soot/vapours, and keep the device clean.
22
off
DS-1
on
DS-2
off
DS-3
off
DS-4
off
DS-5
off
DS-6
off
DS-7
→ ←
DS-8
Example 2
1
2
3,4
5
6
7
8 Store setting: off→ on→ off
off
DS-1
on
DS-2
off
DS-3
on
DS-4
off
DS-5
off
DS-6
on
DS-7
→ ←
DS-8
Example 3
No panel or remote
1
switch connected
No panel or remote
2
switch connected
AGM 14,7 V
3, 4
Frequency: 50 Hz
5
Search mode off
6
AC-in Limit 4 Amp
7
8 Store setting: off→ on→ off
on
off
on
on
on
on
off
→ ←
Panel or remote
switch connected
Panel or remote
switch connected
Tubular plate 15 V
Frequency: 60 Hz
Search mode on
AC-in Limit 12 Amp

Publicité

loading

Ce manuel est également adapté pour:

Blue power easyplus 1600Blue power easyplus 1600va